background image

4-   AUTO - ARMING

      When auto -arming is selected (programable for 2 hours or 15 minutes by installer) the system will arm itself if no 
      movement or any other activations have been detected within the selected time period.

      A second (Installer programmable) option is to enable the entry / exit  zone (zone 1 -  Wired only). 
      When the last activation was detected on zone 1 the system will arm itself at Level ‘D’ after the expiry time . In the event
      where any of the other zones was the last to be triggered the system will arm at Level ‘A’ after the time period expired.
  
      This function is useful when you forget to arm your alarm system. The system will arm itself 15 min /2 hours after you  have
      left the house or went to bed.    The Auto arming option  is set in option register “

08

” bit 8. 

      The End-user can then switch it 

on 

(            ) or     

off

 (           ) 

      Note: Entry / Exit will only function correctly if Zone 1 is the last zone  triggered when you leave your  premises.
      Level ‘A’ will be the “at home /sleep” arming pattern and Level ‘D’ the “away” arming pattern.
      The exit delay is always calculated to be double the entry delay
 

5-   DISABLING THE KEY PADS

      Each key pad can  be disabled individually. To disable temporarily a key pad , enter the user 1 code. Press # for
      approximately 4 seconds followed by the D key. To re-enable the keypad  repeat  the  operation.
   

 

  

REMEMBER THAT THE SECOND TIME THERE  IS  NO INDICATION  FROM THE BUZZER ON THE  KEYPAD 

6-

   TAMPER  ( WIRELESS SENSORS ONLY )

      Circuit that monitors illegal violation of alarm devices when the system is not armed.   When it`s triggered it will send a
      tamper condition to the control room and the 

“WL TBL”

    and

 “TRIGG”

 leds will be illuminated on the keypad with

      buzzer sounding. To cancel the above, enter the user code followed by # #.

7-   WIRELESS ZONE SUPERVISION
      

This feature enables the MINI-TRACER to detect when a wireless  passive is faulty ( NOT REPORTING).

      The user can  program which wireless  zone the MINI-TRACER must monitor. 
      Please note that the wireless passive must be enabled for supervision - pages 8 & 10 and  
      -

See also the wireless detector  instructions.

8-   EVENT MEMORY LOG FACILITY

      The MINI-TRACER-Combo is capable of storing the last 255 events in memory. The installer can view these
      events in case of the user not reporting to a control room. The log facility will display  the day the event was 
      recorded, the time and the reason for the event.

9-   WIRELESS RF BLOCKING

       MINI-TRACER will report a  “System Tamper”  if  Radio Frequency  blocking was detected  on the  system 
      lasting longer then 30 seconds. This is to prevent intruders trying to “JAM” the system.

10-

 

SPI PERIMETER BEAM

      An extra 6 perimeter zones can be installed on the MINI-TRACER. The unit will detect an  activation 
      on the perimeter  beam and sound an audible alarm. 

This condition will not be reported  to control the room

.

      Refer to the instruction of the 

SPI

 beam for installation and programming instructions.

          

   

11- RESPONSE  / GUARD SUPERVISION

      This features allows the control room to supervise all activities undertaken by the response officer.
      For this purpose  the  MINI-TRACER uses  a third remote control code  .
      On this special  Officer  remote control , button A will be the Panic button and button B will be “Guard Responded”. 
      

Please note that this feature is only active for 30 minutes after an  alarm was triggered.

      This Response code  can only be stored by  the 

SELF-LEARNING

 method and not

  MANUALLY

          
  

- 4 -

1

A

+

0

A

+

There are two registers which need to be programmed

:

 

The first sets the number of  the

 

repeater it will use to reach the control room.

The second is if the unit itself becomes a repeater.
Only then will the  MINI-TRACER operate as a simple Store-and-forward repeater  provided the received signals
from the nearby systems carry the same repeater address as the “

I AM 

“ value. See page 8

 

12- REPEATER SELECTION

    

 13- SWINGER ZONE  DISABLE

       If the same  zone  triggers more then 5 times during the same “armed” period the Super-Tracer automatically disables
       those zones until the next arming

 

or until 10 hours have expired since the last alarm triggered by the “swinger” zone.

    

  

M000037 

Содержание Mini TRACER

Страница 1: ...Mini TRACER MAMI MANUFACTURING AND MINOR INVENTIONS Prelim inary issue M000037...

Страница 2: ...RVISION TEST 10 SECTIONAL PERIMETER INTRUSION SPI SYSTEM 11 PRESET PATTERNS A B C AND D 11 SENSITIVITY 11 ARMING 11 EVENT MEMORY LOGGING DISPLAYING 11 INSTALLER KEYPAD PROGRAMMING S ETTING INDIVIDUAL...

Страница 3: ...c EEPROM memory for retention of both options and code selections during power down Optional wired panic button Optional input for key switch operation Programmable silent PANIC alarm Programmable rep...

Страница 4: ...levels each containing a set of zones which you will most likely select in everyday operation You do not have to remember which set you normally arm or set to warning mode The MINI TRACER will memori...

Страница 5: ...an alarm is achieved in the following manner The system will transmit via radio 3 times at random intervals within 25 seconds NOTE After each Radio transmission the system is dormant for 12 seconds to...

Страница 6: ...lease note that the wireless passive must be enabled for supervision pages 8 10 and See also the wireless detector instructions 8 EVENT MEMORY LOG FACILITY The MINI TRACER Combo is capable of storing...

Страница 7: ...protection device which will blow the safety fuse It may therefore be necessary to change the BATTERY and OUTPUT fuses after connecting the battery incorrectly The unit is NOT GUARANTEED for damages...

Страница 8: ...s two exclusive I D Codes a DETECTOR CODE for sensors and detectors and a REMOTE CONTROL CODE for the hand held remote controls an optional 3rd CODE RESPONSE may be used to indicate to the control roo...

Страница 9: ...see TABLE 3 press and buttons together to store the code and exit A 0 1 0 1 0 B 0 1 0 1 0 New C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 0 A B C D KEY BIT NO The new MINI TRACER intro...

Страница 10: ...ON ON USE KS INPUT WITH A KEY SWITCH OFF TRACER OPERATION ON SNIPER OPERATION OFF NO CONFIRMATION REPEATED OFF SPARE OFF NO REPORT OFF AUTO ARM TIME 15 MINUTES ON ARM DISARM CONFIRMATION REPEATED ON S...

Страница 11: ...SMART USE ALL KEYS 1 9 2 3 4 5 6 7 8 TO EXIT PRESS AND HOLD AND THE DECIMAL VALUE OF THE CODE WILL BE SHOWN ON THE DISPLAY Note that code C cannot be entered manually but only through the self learnig...

Страница 12: ...TCH OFF ENTER TO EXIT ENTER 2 LED 2 WILL TURN OFF ENTER 3 LED 3 WILL TURN ON CHECK THAT THIS IS CORRECT ENTER TO EXIT REGISTER NAME INSTALLER CODE REG NO CIRCUIT ZONE OPTION REGISTERS 10 OFF ec ON 15...

Страница 13: ...2 6 0 1 0 Four preset perimeter selections may be pre programmed to coincide with the arm warn levels A B C D This is done as shown below If option 6 of register 01 page8 is set a selection will be a...

Страница 14: ...GISTER NAME INSTALLER CODE REG NO ON UNUSED OFF NOTE 0 9 0 1 0 ERASE KEYBOARD MEMORY HOLD TILL BEEP NOTE THIS OPERATION WILL ERASE ALL PRESENT VALUES AND RESTORE THE FACTORY DEFAULT VALUES INCLUDING K...

Страница 15: ...N RELAY BATTERY FUSE RX 6 5 4 3 2 1 SIREN BUZZ KS B A K P AC 16V BAT Uhf antennae BEAMS BEAMS NO SW LIT BUZ 8 7 6 5 4 3 2 1 TX RX A B SDA SCK LEARN 8 7 6 5 4 3 2 1 LED S TRANSMITTER NOTE 3 REFER TO SP...

Страница 16: ...TARY N O KEY SWITCH _ 14 Figure 2 12V SUPPLY TO THE DETECTOR MINI TRACER CONNECTIONS 2 KEY SWITCH CONNECTIONS M000037 SIREN RELAY BATTERY FUSE AC B A K P 6 5 4 3 2 1 SIREN BUZZ 17V BAT RX KS NORMALLY...

Страница 17: ...RD 1111 4 PASSWORD USER 4 PASSWORD 1111 5 PASSWORD USER 5 PASSWORD 1111 6 PASSWORD USER 6 PASSWORD 1111 7 PASSWORD USER 7 PASSWORD 1111 8 PASSWORD USER 8 PASSWORD 1111 9 PASSWORD USER 9 PASSWORD 1111...

Страница 18: ...Notes M000037...