background image

SPARE

SPARE

SPARE

SPARE

OFF

 = NO REPORT  

OFF 

= NO REPORT  

OFF

 = NO REPORT  

OFF

 = NO REPORT  

SPARE

ON 

= REPORT  ARM / DISARM SIGNALS 

ON

 = REPORT SYSTEM  BATTERY LOW

ON 

= REPORT SYSTEM  MAINS FAILURE

SPARE

 

SPARE

SPARE

0

#

0

2

0

1

0

OPTIONS REGISTER NO. 2

1

2

3

4

5

6

7

8

0

0

0

#

#

#

1

1

1

7

8

9

0

0

0

1

1

1

0

0

0

FACTORY DEFAULTS

For the next 3 options you need to enter a value between 0 and 250.

EXAMPLES:

 -  To set the 

entry-delay 

 to  35 seconds  enter:             

1

 

0

 

0

 

0

 

#

 

1 7     0 3 5

  

(sec)

                      

-  To set the 

check-in interval time

 to 24 hours enter::  

1

 

0

 

0

 

0

 

# 1 8    0 2 4  (hrs)

                      -  

To set the

 siren duration to 4 minutes 

 enter:  

         1

 

0

 

0

 

0

 

#

 

1 9    2 4 0  (4 x 60) (sec)

N.B.  - A  CHECK-IN INTERVAL  VALUE OF  "0"    WILL  AUTOMATICALLY DISABLE THE OPTION ( NO CHECKING-IN  TRANSMISSION ).
         - THE “EXIT” DELAY IS AUTOMATICALLY SET TO DOUBLE THE  “ENTRY” DELAY

ENTRY / EXIT DELAY VALUE (SEC)

CHECK-IN  INTERVAL (HRS)

SIREN DURATION (SEC)

OFF

 =  SILENT PANIC BUTTON

OFF

 = NORMAL OPERATION

OFF

 = AUXIL. SIGNALS ON BUZZER ONLY

SPARE

 

ON

 = SIREN WITH PANIC BUTTON

ON

 = MULTI-USER OPERATION

ON

 = AUXIL. SIGNALS ON BUZZER & SIREN 

SPARE

 

0

#

0

1

0

1

0

OPTIONS REGISTER NO. 1

= OFF

= ON

NOTE:

1

2

3

4

5

6

7

8

OFF 

= USE KS INPUT FOR PANIC BUTTON 

ON

 = USE KS INPUT  WITH A KEY-SWITCH

OFF 

= TRACER OPERATION

ON

 = SNIPER OPERATION 

OFF 

= NO CONFIRMATION(REPEATED)  

OFF 

= SPARE

OFF 

= NO REPORT

OFF 

= AUTO ARM TIME - 15 MINUTES

ON

 = ARM/DISARM CONFIRMATION(REPEATED) 

ON

 = SPARE 

ON

 = REPORT WIRELESS SUPERVISION

ON

 = AUTO-ARM TIME - 2HRS

OFF

= AUTO ARM - DISABLED

ON 

= AUTO ARM ENABLED

0

#

0

8

0

1

0

OPTIONS (MODE) REGISTER NO.8

1

2

3

4

5

6

7

8

- 8 -

F

ACT

OR

Y

 DEF

AUL

T

F

ACT

OR

Y

 DEF

AUL

T

F

ACT

OR

Y

 DEF

AUL

T

ON

 = WIRELESS RF BLOCKING ENABLED 

OFF 

=  WIRELESS RF BLOCKING DISABLED 

ON

 = REPORT “BATTERY LOW” IN  SENSORS 

ON

 = PERIMETER MASK LINKED TO ARM LEVEL 

OFF

 = PERIMETER AND  ARM MASKS NOT LINKED

OFF

 = AUDIBLE  ARM/DISARM  ON KEY-PAD 

OFF

 = DISABLE WARNING VIA REMOTE 

ON

 = SILENT  ARM/DISARM  ON KEY-PAD 

ON

 = ENABLE WARNING VIA REMOTE 

New!!

5

4

0

0

0

2

3

2

4

(35SEC)

(24HRS)

(240SEC)

0

#

0

1

0

    I AM REPEATER “ 1”

 REPEATER “1”

New!!

New!!

ON

 = SNIPER OPERATION 

0

#

0

1

0

Set  the  “I AM”   Repeater  Number

2

1

0

1

2

#

Display the  Repeater  Number

*

THE  CURRENT REPEATER
NUMBER WILL BE INDICATED.

This feature can only be used if the MINI-TRACER itself

 

is setup

 

TO BE A REPEATER

 

with the

 

NECESSARY HARDWARE

 and OPTION 6 of Option-Register  8 is ON

.

0

#

0

1

0

Set  the  Repeater  Number

2

1

0

#

0

#

0

1

0

1

2

Display the  “I AM ” Repeater  Number

*

THE  CURRENT REPEATER
NUMBER WILL BE INDICATED.

New!!

PROGRAMMING THE FIELD REPEATER NUMBER 

 PROGRAMMING

SPARE

SPARE

M000037 

Содержание Mini TRACER

Страница 1: ...Mini TRACER MAMI MANUFACTURING AND MINOR INVENTIONS Prelim inary issue M000037...

Страница 2: ...RVISION TEST 10 SECTIONAL PERIMETER INTRUSION SPI SYSTEM 11 PRESET PATTERNS A B C AND D 11 SENSITIVITY 11 ARMING 11 EVENT MEMORY LOGGING DISPLAYING 11 INSTALLER KEYPAD PROGRAMMING S ETTING INDIVIDUAL...

Страница 3: ...c EEPROM memory for retention of both options and code selections during power down Optional wired panic button Optional input for key switch operation Programmable silent PANIC alarm Programmable rep...

Страница 4: ...levels each containing a set of zones which you will most likely select in everyday operation You do not have to remember which set you normally arm or set to warning mode The MINI TRACER will memori...

Страница 5: ...an alarm is achieved in the following manner The system will transmit via radio 3 times at random intervals within 25 seconds NOTE After each Radio transmission the system is dormant for 12 seconds to...

Страница 6: ...lease note that the wireless passive must be enabled for supervision pages 8 10 and See also the wireless detector instructions 8 EVENT MEMORY LOG FACILITY The MINI TRACER Combo is capable of storing...

Страница 7: ...protection device which will blow the safety fuse It may therefore be necessary to change the BATTERY and OUTPUT fuses after connecting the battery incorrectly The unit is NOT GUARANTEED for damages...

Страница 8: ...s two exclusive I D Codes a DETECTOR CODE for sensors and detectors and a REMOTE CONTROL CODE for the hand held remote controls an optional 3rd CODE RESPONSE may be used to indicate to the control roo...

Страница 9: ...see TABLE 3 press and buttons together to store the code and exit A 0 1 0 1 0 B 0 1 0 1 0 New C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 0 A B C D KEY BIT NO The new MINI TRACER intro...

Страница 10: ...ON ON USE KS INPUT WITH A KEY SWITCH OFF TRACER OPERATION ON SNIPER OPERATION OFF NO CONFIRMATION REPEATED OFF SPARE OFF NO REPORT OFF AUTO ARM TIME 15 MINUTES ON ARM DISARM CONFIRMATION REPEATED ON S...

Страница 11: ...SMART USE ALL KEYS 1 9 2 3 4 5 6 7 8 TO EXIT PRESS AND HOLD AND THE DECIMAL VALUE OF THE CODE WILL BE SHOWN ON THE DISPLAY Note that code C cannot be entered manually but only through the self learnig...

Страница 12: ...TCH OFF ENTER TO EXIT ENTER 2 LED 2 WILL TURN OFF ENTER 3 LED 3 WILL TURN ON CHECK THAT THIS IS CORRECT ENTER TO EXIT REGISTER NAME INSTALLER CODE REG NO CIRCUIT ZONE OPTION REGISTERS 10 OFF ec ON 15...

Страница 13: ...2 6 0 1 0 Four preset perimeter selections may be pre programmed to coincide with the arm warn levels A B C D This is done as shown below If option 6 of register 01 page8 is set a selection will be a...

Страница 14: ...GISTER NAME INSTALLER CODE REG NO ON UNUSED OFF NOTE 0 9 0 1 0 ERASE KEYBOARD MEMORY HOLD TILL BEEP NOTE THIS OPERATION WILL ERASE ALL PRESENT VALUES AND RESTORE THE FACTORY DEFAULT VALUES INCLUDING K...

Страница 15: ...N RELAY BATTERY FUSE RX 6 5 4 3 2 1 SIREN BUZZ KS B A K P AC 16V BAT Uhf antennae BEAMS BEAMS NO SW LIT BUZ 8 7 6 5 4 3 2 1 TX RX A B SDA SCK LEARN 8 7 6 5 4 3 2 1 LED S TRANSMITTER NOTE 3 REFER TO SP...

Страница 16: ...TARY N O KEY SWITCH _ 14 Figure 2 12V SUPPLY TO THE DETECTOR MINI TRACER CONNECTIONS 2 KEY SWITCH CONNECTIONS M000037 SIREN RELAY BATTERY FUSE AC B A K P 6 5 4 3 2 1 SIREN BUZZ 17V BAT RX KS NORMALLY...

Страница 17: ...RD 1111 4 PASSWORD USER 4 PASSWORD 1111 5 PASSWORD USER 5 PASSWORD 1111 6 PASSWORD USER 6 PASSWORD 1111 7 PASSWORD USER 7 PASSWORD 1111 8 PASSWORD USER 8 PASSWORD 1111 9 PASSWORD USER 9 PASSWORD 1111...

Страница 18: ...Notes M000037...

Страница 19: ...MAMI MANUFACTURING AND MINOR INVENTIONS M000037...

Отзывы: