   GENERAL FEATURES:

T

he 

"MINI-TRACER" 

is a microprocessor based ALARM PANEL designed  to  perform  all  the  functions

  associated  with the monitoring of alarm conditions,  in  both wired and wireless environment,  and  subsequent 
 transmission by Radio  to  a  REMOTE  MONITORING CONTROL ROOM.
The  

"MINI-TRACER"  not only conforms with  SAIDSA specifications but offers many more features 

which are not available in traditional alarm panels. 

The  

"MINI-TRACER" is capable of reporting the condition of all 6 zones in one transmission giving the full

current status of the alarm panel

These features  make the 

"MINI-TRACER" 

a  versatile, efficient and most  innovative  ALARM  CONTROL PANEL

- Supports   2

 

key pads and /or displays. 

-

 6 zones

 

BOTH  WIRED 

 

and  /or 6  WIRELESS

.

- Arm/disarm and warning selection  via 

Keypad, Key-Switch or Remote Control

- Normal or  multi-user operation ( 4 partitions).
- Remembers all selections during power failures and  

will resume from the last status.                                                                                   

- Supervised alarm circuits/zones  with end of  line resistors (2k7)

.

- Programmable "

entry / exit  delay

"

 .

- Programmable  siren activation  on individual  zones.

UHF 

 

RADIO  transmitter.  

- Built-in battery  1.5 A charger for  Stand-by 7 A/h battery (48 hrs autonomy on average installation ).
- Buzzer output for auxiliary  signals (arm, disarm, battery-low etc....).

EEPROM

 

 memory  for retention  of both options a

n

d code selections during  "power-down".

- Optional wired panic button
- Optional input for key-switch operation
- Programmable 

silent PANIC

 

alarm.

- Programmable reporting  of 

battery low condition in each  wireless sensor

 

.

- Programmable reporting  of 

system

 

mains failure, mains restoral, system battery low

 

 and restoral.

- Programmable reporting  of 

arm and disarm with user identification.

 

- Programmable 

Auto arming

 

with optional entry-exit

 

feature ( hands free).

Subscriber ID code 

a

nd options fully programmabl

e

 by the installer

.

-  

TEST

 

transmission can be sent  to contr

o

l room via  the remote control or keypad.

- Programmable  

"check-in"

 

transmission  from  1 to 250 hours

.

- Four preset  active  levels  “

A

,

 B, C, or D

- Diagnostic  for  testing  wireless  devices. 
- Easy programming and display of  current  options  and  settings . 
- Programmable alarm reporting  on individual zones.
- Each keypad can be switched off individually.          
- Self Learning function for the Remote Control code and Wireless Detectors.                                                                                                    
- Supports both Old and New report  protocols and wireless codes.                                                                                                 
- Quick setting of the four preset levels: 

“A, B ,C or D”  t

o ARM     

- Quick setting of the four preset levels: 

“A, B ,C or D”  t

o WARN                                                        

- Keypad  system security identification feature.                                                                                       
- Duress code.                                                                                                 
- Tamper on Wireless Detectors
- Battery low on wireless detectors                                                                                                     
- Wireless detectors  Supervision   
- Keypad wrong-code lockout                                                                                                     
- 255 Event logging in non volatile memory.                                                                                                       
- Zone “swinger” to  automatically disable  false triggering zones
- 6 sector  perimeter  expander interface, for SPI beams                                                   

 

M000037 

Содержание Mini TRACER

Страница 1: ...Mini TRACER MAMI MANUFACTURING AND MINOR INVENTIONS Prelim inary issue M000037...

Страница 2: ...RVISION TEST 10 SECTIONAL PERIMETER INTRUSION SPI SYSTEM 11 PRESET PATTERNS A B C AND D 11 SENSITIVITY 11 ARMING 11 EVENT MEMORY LOGGING DISPLAYING 11 INSTALLER KEYPAD PROGRAMMING S ETTING INDIVIDUAL...

Страница 3: ...c EEPROM memory for retention of both options and code selections during power down Optional wired panic button Optional input for key switch operation Programmable silent PANIC alarm Programmable rep...

Страница 4: ...levels each containing a set of zones which you will most likely select in everyday operation You do not have to remember which set you normally arm or set to warning mode The MINI TRACER will memori...

Страница 5: ...an alarm is achieved in the following manner The system will transmit via radio 3 times at random intervals within 25 seconds NOTE After each Radio transmission the system is dormant for 12 seconds to...

Страница 6: ...lease note that the wireless passive must be enabled for supervision pages 8 10 and See also the wireless detector instructions 8 EVENT MEMORY LOG FACILITY The MINI TRACER Combo is capable of storing...

Страница 7: ...protection device which will blow the safety fuse It may therefore be necessary to change the BATTERY and OUTPUT fuses after connecting the battery incorrectly The unit is NOT GUARANTEED for damages...

Страница 8: ...s two exclusive I D Codes a DETECTOR CODE for sensors and detectors and a REMOTE CONTROL CODE for the hand held remote controls an optional 3rd CODE RESPONSE may be used to indicate to the control roo...

Страница 9: ...see TABLE 3 press and buttons together to store the code and exit A 0 1 0 1 0 B 0 1 0 1 0 New C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 0 A B C D KEY BIT NO The new MINI TRACER intro...

Страница 10: ...ON ON USE KS INPUT WITH A KEY SWITCH OFF TRACER OPERATION ON SNIPER OPERATION OFF NO CONFIRMATION REPEATED OFF SPARE OFF NO REPORT OFF AUTO ARM TIME 15 MINUTES ON ARM DISARM CONFIRMATION REPEATED ON S...

Страница 11: ...SMART USE ALL KEYS 1 9 2 3 4 5 6 7 8 TO EXIT PRESS AND HOLD AND THE DECIMAL VALUE OF THE CODE WILL BE SHOWN ON THE DISPLAY Note that code C cannot be entered manually but only through the self learnig...

Страница 12: ...TCH OFF ENTER TO EXIT ENTER 2 LED 2 WILL TURN OFF ENTER 3 LED 3 WILL TURN ON CHECK THAT THIS IS CORRECT ENTER TO EXIT REGISTER NAME INSTALLER CODE REG NO CIRCUIT ZONE OPTION REGISTERS 10 OFF ec ON 15...

Страница 13: ...2 6 0 1 0 Four preset perimeter selections may be pre programmed to coincide with the arm warn levels A B C D This is done as shown below If option 6 of register 01 page8 is set a selection will be a...

Страница 14: ...GISTER NAME INSTALLER CODE REG NO ON UNUSED OFF NOTE 0 9 0 1 0 ERASE KEYBOARD MEMORY HOLD TILL BEEP NOTE THIS OPERATION WILL ERASE ALL PRESENT VALUES AND RESTORE THE FACTORY DEFAULT VALUES INCLUDING K...

Страница 15: ...N RELAY BATTERY FUSE RX 6 5 4 3 2 1 SIREN BUZZ KS B A K P AC 16V BAT Uhf antennae BEAMS BEAMS NO SW LIT BUZ 8 7 6 5 4 3 2 1 TX RX A B SDA SCK LEARN 8 7 6 5 4 3 2 1 LED S TRANSMITTER NOTE 3 REFER TO SP...

Страница 16: ...TARY N O KEY SWITCH _ 14 Figure 2 12V SUPPLY TO THE DETECTOR MINI TRACER CONNECTIONS 2 KEY SWITCH CONNECTIONS M000037 SIREN RELAY BATTERY FUSE AC B A K P 6 5 4 3 2 1 SIREN BUZZ 17V BAT RX KS NORMALLY...

Страница 17: ...RD 1111 4 PASSWORD USER 4 PASSWORD 1111 5 PASSWORD USER 5 PASSWORD 1111 6 PASSWORD USER 6 PASSWORD 1111 7 PASSWORD USER 7 PASSWORD 1111 8 PASSWORD USER 8 PASSWORD 1111 9 PASSWORD USER 9 PASSWORD 1111...

Страница 18: ...Notes M000037...

Страница 19: ...MAMI MANUFACTURING AND MINOR INVENTIONS M000037...

Отзывы: