    Summary of   ALL  Key-Pad entries 

PROGRAMMING  THE OPTION REGISTERS (ONLY THROUGH  TO THE INSTALLER PASSWORD

)

1000 # 0 1     = SET OPTIONS 1 OF THE SYSTEM
1000 # 0 2     = SET OPTIONS 2 OF THE SYSTEM
1000 # 0 3     = SPARE
1000 # 0 4     = SET DET. DELAY FOR EACH ZONE.
1000 # 0 5     = SET SIREN ACTIVATION.
1000 # 0 6     = SET OPEN / CLOSE REPORTING
1000 # 0 7     = SET ALM / RESTORE REPORTING
1000 # 0 8     = MODE REGISTER
1000 # 0 9     = ERASE EEPROM IN THE CONTOLUNIT
1000 # 0 A     = SET LEVEL A
1000 # 0 B    = SET LEVEL B
1000 # 0 C    = SET LEVEL C
1000 # 0 D    = SET LEVEL D
1000 # 1 3    = TRANSMITTER INHIBIT TIME
1000 # 1 4    = ALARM REPORTING ZONES
1000 # 1 5    = PERMANENT ACTIVE ZONE
1000 # 1 6    = ENTRY/EXIT DELAY
1000 # 1 7    = ENTRY/EXIT DELAY VALUE
1000 # 1 8    = CHECK-IN TIME
1000 # 1 9    = SIREN DURATION

1000 # 1 A    = SET  DIP SW OF SYSTEM
1000 # 1 B    = SET  DIP SW OF REMOTE
1000 # 1 C # = PROG CUSTOMER ID CODE
1000 # 1 C *  = DISP CUSTOMER ID CODE
1000 # 1 D    = SELF LEARNING MODE  ("0"=EXIT)
1000 # 2 0 #  = PROGRAM  “NEXT” REPEATER Number
1000 # 2 0 *  = DISPLAY  “NEXT”REPEATER Number 

         

1000 # 2 1 #  = PROGRAM the REPEATER Number
1000 # 2 1 *  = DISPLAY  the REPEATER Number 

         

1000 # 2 2    = PROGRAM ACTIVE WIRELESS SENSOR (SUPERVISION)
1000 # 2 3    = AUTO ASSESS ACTIVE PERIMETER BEAMS (SPI)
1000 # 2 4    = PROGRAM SPI MASTER OPTIONS
1000 # 2 5    = PROGRAM ACTIVE PERIMETER BEAMS (SPI)
1000 # 2 9    = ERASE EEPROM IN BOTH KEYPAD AND THE CONTOLUNIT
1000 # 3 3    = DISPLAY ALARM LOG FILE
1000 # 3 A    = SET PERIMETER PATTERN “A”
1000 # 3 B    = SET PERIMETER PATTERN “B”
1000 # 3 C    = SET PERIMETER PATTERN “C”
1000 # 3 D    = SET PERIMETER PATTERN “D”

CHANGING PASSWORDS (USING THE DEFAULT / EXISTING  PASSWORDS)

HOW  THE INSTALLER CAN CHANGE PASSWORDS

1000 #--># C 0 [PASSWORD] = INSTALL PASSWORD
1000 #--># C 1 [PASSWORD] = USER 1  PASSWORD
1000 #--># C 2 [PASSWORD] = USER 2  PASSWORD    
1000 #--># C 3 [PASSWORD] = USER 3  PASSWORD
1000 #--># C 4 [PASSWORD] = USER 4  PASSWORD
1000 #--># C 5 [PASSWORD] = USER 5  PASSWORD
1000 #--># C 6 [PASSWORD] = USER 6  PASSWORD
1000 #--># C 7 [PASSWORD] = USER 7  PASSWORD
1000 #--># C 8 [PASSWORD] = USER 8  PASSWORD
1000 #--># C 9 [PASSWORD] = USER 9  PASSWORD
1000 #--># C A [PASSWORD] = USER 10 PASSWORD

HOW  USER-1  (MASTER) CAN CHANGE PASSWORDS

1111 #--># 1 [PASSWORD] = USER 1  PASSWORD
1111 #--># 2 [PASSWORD] = USER 2  PASSWORD
1111 #--># 3 [PASSWORD] = USER 3  PASSWORD
1111 #--># 4 [PASSWORD] = USER 4  PASSWORD
1111 #--># 5 [PASSWORD] = USER 5  PASSWORD
1111 #--># 6 [PASSWORD] = USER 6  PASSWORD
1111 #--># 7 [PASSWORD] = USER 7  PASSWORD
1111 #--># 8 [PASSWORD] = USER 8  PASSWORD
1111 #--># 9 [PASSWORD] = USER 9  PASSWORD
1111 #--># A [PASSWORD] = USER 10 PASSWORD

HOW USERS 2,3,4 & 5 CAN  CHANGE THEIR OWN PASSWORDS

2222 #--># = CHANGE PASSWORD USER 2
4444 #--># = CHANGE PASSWORD USER 4

3333 #--># = CHANGE PASSWORD USER 3
5555 #--># = CHANGE PASSWORD USER 5

CHOOSING ARM / WARN LEVELS IN MULTI-USER MODE 

2222 # A     = ARM LEVEL B (USER 2)
3333 # A     = ARM LEVEL C (USER 3)
4444 # A     = ARM LEVEL D (USER 4)
5555 # A     = ARM LEVEL A (USER 5)

2222 # #   = DISARM LEVEL B (USER 2)
3333 # #   = DISARM LEVEL C (USER 3)
4444 # #   = DISARM LEVEL D (USER 4)
5555 # #   = DISARM LEVEL A (USER 5)

2222 # [Y] B  = WARNING MULTIPLE ZONES (ONLY WITHIN THE MASK)                       2222 # [Y] A = ARMING MULTIPLE ZONES (ONLY WITHIN THE MASK)

CHOOSING ARM / WARN LEVELS AND DISARMING  IN NORMAL MODE 

1111  # [Z] A = ARM SET BY  USER 1
2222 # [Z] A = ARM  SET BY  USER 2
3333 # [Z] A = ARM  SET BY  USER 3
4444 # [Z] A = ARM  SET BY  USER 4

1111  # #   = DISARM SYSTEM
2222 # #   = DISARM SYSTEM
3333 # #   = DISARM SYSTEM
4444 # #   = DISARM SYSTEM

DUAL KEY OPERATIONS AVAILABLE TO THE USER

[A&0] -->[A&0]   = DISABLE AUTO-ARMING
[A&1] -->[A&1]   = ENABLE AUTO-ARMING 
[ *& #] --> [*&#]  = SEND PANIC SIGNAL
[1&3] --> [1&3]   = MEDICAL
[4&6] --> [4&6]   = SEND TEST SIGNAL

NOTES:

  A-->A   Means: Press and hold the A key until it beeps
 [*&A -->*&A]   Means: Press and hold the * and  the  A keys until it beeps
 [ Y ]     Means: Any COMBINATIONS OF numbers 1,2,3,4,5,6,7 or 8
 [ Z ]      Means: any  A, B, C, D key  or any  combination of 1,2,3,4,5,6,7 or 8 keys
 [  *  ]    Denotes the value when the correct  password has been entered  
 [7&9]   Means:  Press  BOTH KEYS (7&9)  at the same time

PROGRAMMING THE SPECIFIC  KEYPAD OPTIONS ( ONLY AVAILABLE THROUGH THE INSTALLER  PASSWORD

 
1000 #--># 1    = ENABLE LOCAL KEYPAD
1000 #--># 3    = SET LOCAL BEEPER FUNCTIONS ON KP
1000 #--># 4    = CHANGE KEYPAD SYSTEM  ID

OTHER  KEY OPERATIONS AVAILABLE TO THE USER

1111  # [Z] B = WARN SET BY  USER 1
2222 # [Z] B = WARN SET BY  USER 2
3333 # [Z] B = WARN SET BY  USER 3
4444 # [Z] B = WARN SET BY  USER 4

A --> A   = SET  ARM LEVEL A
B --> B   = SET ARM LEVEL B
C --> C   = SET ARM LEVEL C
D --> D   = SET ARM LEVEL D

* & A -->  * & A   = SET  WARN-LEVEL A
* & B --> * & B   = SET  WARN-LEVEL B
* & C --> * & C   = SET  WARN-LEVEL C
* & D --> * & D   = SET  WARN-LEVEL D

???? # 0 [Y] # = SET PERIMETER BEAM MASK
1111 #--># D = DISABLE/ENABLE THIS KEYPAD
1111 # 9 [Y] [Y] SET RESPONSE VALUE FOR SECTORS IN THE SPI

 Appendix “A”                   

1000 #--># 9     = CLEAR EEPROM ON LOCAL KP
1000 #--># D   = SET KEYPAD   NUMBER

M000037 

Содержание Mini TRACER

Страница 1: ...Mini TRACER MAMI MANUFACTURING AND MINOR INVENTIONS Prelim inary issue M000037...

Страница 2: ...RVISION TEST 10 SECTIONAL PERIMETER INTRUSION SPI SYSTEM 11 PRESET PATTERNS A B C AND D 11 SENSITIVITY 11 ARMING 11 EVENT MEMORY LOGGING DISPLAYING 11 INSTALLER KEYPAD PROGRAMMING S ETTING INDIVIDUAL...

Страница 3: ...c EEPROM memory for retention of both options and code selections during power down Optional wired panic button Optional input for key switch operation Programmable silent PANIC alarm Programmable rep...

Страница 4: ...levels each containing a set of zones which you will most likely select in everyday operation You do not have to remember which set you normally arm or set to warning mode The MINI TRACER will memori...

Страница 5: ...an alarm is achieved in the following manner The system will transmit via radio 3 times at random intervals within 25 seconds NOTE After each Radio transmission the system is dormant for 12 seconds to...

Страница 6: ...lease note that the wireless passive must be enabled for supervision pages 8 10 and See also the wireless detector instructions 8 EVENT MEMORY LOG FACILITY The MINI TRACER Combo is capable of storing...

Страница 7: ...protection device which will blow the safety fuse It may therefore be necessary to change the BATTERY and OUTPUT fuses after connecting the battery incorrectly The unit is NOT GUARANTEED for damages...

Страница 8: ...s two exclusive I D Codes a DETECTOR CODE for sensors and detectors and a REMOTE CONTROL CODE for the hand held remote controls an optional 3rd CODE RESPONSE may be used to indicate to the control roo...

Страница 9: ...see TABLE 3 press and buttons together to store the code and exit A 0 1 0 1 0 B 0 1 0 1 0 New C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 0 A B C D KEY BIT NO The new MINI TRACER intro...

Страница 10: ...ON ON USE KS INPUT WITH A KEY SWITCH OFF TRACER OPERATION ON SNIPER OPERATION OFF NO CONFIRMATION REPEATED OFF SPARE OFF NO REPORT OFF AUTO ARM TIME 15 MINUTES ON ARM DISARM CONFIRMATION REPEATED ON S...

Страница 11: ...SMART USE ALL KEYS 1 9 2 3 4 5 6 7 8 TO EXIT PRESS AND HOLD AND THE DECIMAL VALUE OF THE CODE WILL BE SHOWN ON THE DISPLAY Note that code C cannot be entered manually but only through the self learnig...

Страница 12: ...TCH OFF ENTER TO EXIT ENTER 2 LED 2 WILL TURN OFF ENTER 3 LED 3 WILL TURN ON CHECK THAT THIS IS CORRECT ENTER TO EXIT REGISTER NAME INSTALLER CODE REG NO CIRCUIT ZONE OPTION REGISTERS 10 OFF ec ON 15...

Страница 13: ...2 6 0 1 0 Four preset perimeter selections may be pre programmed to coincide with the arm warn levels A B C D This is done as shown below If option 6 of register 01 page8 is set a selection will be a...

Страница 14: ...GISTER NAME INSTALLER CODE REG NO ON UNUSED OFF NOTE 0 9 0 1 0 ERASE KEYBOARD MEMORY HOLD TILL BEEP NOTE THIS OPERATION WILL ERASE ALL PRESENT VALUES AND RESTORE THE FACTORY DEFAULT VALUES INCLUDING K...

Страница 15: ...N RELAY BATTERY FUSE RX 6 5 4 3 2 1 SIREN BUZZ KS B A K P AC 16V BAT Uhf antennae BEAMS BEAMS NO SW LIT BUZ 8 7 6 5 4 3 2 1 TX RX A B SDA SCK LEARN 8 7 6 5 4 3 2 1 LED S TRANSMITTER NOTE 3 REFER TO SP...

Страница 16: ...TARY N O KEY SWITCH _ 14 Figure 2 12V SUPPLY TO THE DETECTOR MINI TRACER CONNECTIONS 2 KEY SWITCH CONNECTIONS M000037 SIREN RELAY BATTERY FUSE AC B A K P 6 5 4 3 2 1 SIREN BUZZ 17V BAT RX KS NORMALLY...

Страница 17: ...RD 1111 4 PASSWORD USER 4 PASSWORD 1111 5 PASSWORD USER 5 PASSWORD 1111 6 PASSWORD USER 6 PASSWORD 1111 7 PASSWORD USER 7 PASSWORD 1111 8 PASSWORD USER 8 PASSWORD 1111 9 PASSWORD USER 9 PASSWORD 1111...

Страница 18: ...Notes M000037...

Страница 19: ...MAMI MANUFACTURING AND MINOR INVENTIONS M000037...