background image

-2-

                     

The 

"MINI-TRACER"

 is capable of  monitoring 

BOTH WIRED and 

 

WIRE-LESS

 detector circuits at the same 

time.

 

A  

REMOTE PANIC BUTTON

  option is  built in as a standard feature.

The "MINI-TRACER"

 will send an alarm/report   whe

n

ever the following inputs are triggered:

- Any of the 6 wired active inputs.
- Any of the 6 wireless active inputs.
- Remote panic button.
- Supervisory signals such as:
                  - battery low in the wireless sensors.                         - low battery in the system.
                 - 

 

arm / disarm.                                                            - battery restored  in system.

                 -  mains failure                                                            -

 

 test transmission

                 -  mains restored                                                         - Tamper & password change
                 -  panic  button                                                   
For complete  application flexibility the six wired inputs may be programmed  to  send  an alarm whenever one of the
following conditions occur:
  - When the external circuit is opened   (

Normally Closed circuit).

  - When the external circuit is closed   (

Normally Open circuit).

  - Both when the external circuit is 

Opened

 

or

 

Closed.

    (In this case it is possible to program any of the circuits as an "alarm circuit" or a "door entry monitoring circuit").
  - When the trigger condition remains for  longer than 15 sec (slow detection).

For example

 

You may require that the particular circuit calls the control room both when  an alarm occurs

 and when  it is restored, or that a particular circuit calls the control room both when a door is locked or unlocked.

The six wireless  inputs  work parallel to  the wired inputs

 

and therefore  share  all the available 

optional features such as:
 - individual siren activation selection                        - individual "ENTRY/EXIT DELAY" selection
 - individual "warning only" selection                         - individual "24 hrs" ready activation.

A great feature of    the 

‘MINI-TRACER"  

is  the fact that it is fully  programmable to suit every possible

 

requirement.   

You can  for instance  define 4 levels each containing a set of  zones  which you will most likely  select in everyday 
operation.  You do not have to remember which set you normally arm or set to warning mode.

The 

"MINI-TRACER

"

 

will  memorize the  four  patterns  for you and so when  arming the system, automatically 

step through these preset patterns allowing you to stop at the  one you desire.  These  patterns may  be  changed  
at  will by the installer or by the customer  using  the two buttons  on the hand-held remote control. 
These preset levels can be

  “Quick selected” . See “long-key” on  table of key entries

ALL COMMANDS and INDICATIONS are  performed / shown on up to 4  wall mounted Keypads / Display units .

The Key Pad / DISPLAY units can display the following information: 
-

  the wired/wireless sensor  which caused the alarm.        -  the wired/wireless sensor  which caused the warning signal.

-  the perimeter beam which was activated.                        -  system armed / disarmed indication. 
-  which zone is set to  24hrs, armed  or on warning.          -  Entry / exit delay activated.
-  mains failure has occurred.                                              -  system battery is only 80 % charged.
-  system has triggered and the signal was sent to control room.
       
The GREEN  numeric display shows the Sector  which was activated on the  perimeter beams.
 
The RED numeric display shows the type of transmission which was sent to the control room e.g.:- 
                           -  Numbers 

1 to 6 

indicating the alarm Zone  which was triggered.

                           - The letter 

"p" 

indicating  panic button activation.

                           - The letter " 

" indicating  test transmission.

                           - The letter " 

" indicating  battery low in one of the wireless sensors.

                           - The letter " 

" indicating  that the system had a reset.

                           - The letter “ 

” indicating a warning or a call facility.

                           - The letter “ 

” indicating the system is not programmed yet.

                           - The letter “ 

” indicating a tamper condition is present. 

                           - The letter “ 

” indicates that the ID of the keypad is not the same as the ID of the Tracer 

                           - The letter ” 

” indicates wireless Radio Frequency blocking.

             GENERAL INFORMATION

M000037 

Содержание Mini TRACER

Страница 1: ...Mini TRACER MAMI MANUFACTURING AND MINOR INVENTIONS Prelim inary issue M000037...

Страница 2: ...RVISION TEST 10 SECTIONAL PERIMETER INTRUSION SPI SYSTEM 11 PRESET PATTERNS A B C AND D 11 SENSITIVITY 11 ARMING 11 EVENT MEMORY LOGGING DISPLAYING 11 INSTALLER KEYPAD PROGRAMMING S ETTING INDIVIDUAL...

Страница 3: ...c EEPROM memory for retention of both options and code selections during power down Optional wired panic button Optional input for key switch operation Programmable silent PANIC alarm Programmable rep...

Страница 4: ...levels each containing a set of zones which you will most likely select in everyday operation You do not have to remember which set you normally arm or set to warning mode The MINI TRACER will memori...

Страница 5: ...an alarm is achieved in the following manner The system will transmit via radio 3 times at random intervals within 25 seconds NOTE After each Radio transmission the system is dormant for 12 seconds to...

Страница 6: ...lease note that the wireless passive must be enabled for supervision pages 8 10 and See also the wireless detector instructions 8 EVENT MEMORY LOG FACILITY The MINI TRACER Combo is capable of storing...

Страница 7: ...protection device which will blow the safety fuse It may therefore be necessary to change the BATTERY and OUTPUT fuses after connecting the battery incorrectly The unit is NOT GUARANTEED for damages...

Страница 8: ...s two exclusive I D Codes a DETECTOR CODE for sensors and detectors and a REMOTE CONTROL CODE for the hand held remote controls an optional 3rd CODE RESPONSE may be used to indicate to the control roo...

Страница 9: ...see TABLE 3 press and buttons together to store the code and exit A 0 1 0 1 0 B 0 1 0 1 0 New C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 0 A B C D KEY BIT NO The new MINI TRACER intro...

Страница 10: ...ON ON USE KS INPUT WITH A KEY SWITCH OFF TRACER OPERATION ON SNIPER OPERATION OFF NO CONFIRMATION REPEATED OFF SPARE OFF NO REPORT OFF AUTO ARM TIME 15 MINUTES ON ARM DISARM CONFIRMATION REPEATED ON S...

Страница 11: ...SMART USE ALL KEYS 1 9 2 3 4 5 6 7 8 TO EXIT PRESS AND HOLD AND THE DECIMAL VALUE OF THE CODE WILL BE SHOWN ON THE DISPLAY Note that code C cannot be entered manually but only through the self learnig...

Страница 12: ...TCH OFF ENTER TO EXIT ENTER 2 LED 2 WILL TURN OFF ENTER 3 LED 3 WILL TURN ON CHECK THAT THIS IS CORRECT ENTER TO EXIT REGISTER NAME INSTALLER CODE REG NO CIRCUIT ZONE OPTION REGISTERS 10 OFF ec ON 15...

Страница 13: ...2 6 0 1 0 Four preset perimeter selections may be pre programmed to coincide with the arm warn levels A B C D This is done as shown below If option 6 of register 01 page8 is set a selection will be a...

Страница 14: ...GISTER NAME INSTALLER CODE REG NO ON UNUSED OFF NOTE 0 9 0 1 0 ERASE KEYBOARD MEMORY HOLD TILL BEEP NOTE THIS OPERATION WILL ERASE ALL PRESENT VALUES AND RESTORE THE FACTORY DEFAULT VALUES INCLUDING K...

Страница 15: ...N RELAY BATTERY FUSE RX 6 5 4 3 2 1 SIREN BUZZ KS B A K P AC 16V BAT Uhf antennae BEAMS BEAMS NO SW LIT BUZ 8 7 6 5 4 3 2 1 TX RX A B SDA SCK LEARN 8 7 6 5 4 3 2 1 LED S TRANSMITTER NOTE 3 REFER TO SP...

Страница 16: ...TARY N O KEY SWITCH _ 14 Figure 2 12V SUPPLY TO THE DETECTOR MINI TRACER CONNECTIONS 2 KEY SWITCH CONNECTIONS M000037 SIREN RELAY BATTERY FUSE AC B A K P 6 5 4 3 2 1 SIREN BUZZ 17V BAT RX KS NORMALLY...

Страница 17: ...RD 1111 4 PASSWORD USER 4 PASSWORD 1111 5 PASSWORD USER 5 PASSWORD 1111 6 PASSWORD USER 6 PASSWORD 1111 7 PASSWORD USER 7 PASSWORD 1111 8 PASSWORD USER 8 PASSWORD 1111 9 PASSWORD USER 9 PASSWORD 1111...

Страница 18: ...Notes M000037...

Страница 19: ...MAMI MANUFACTURING AND MINOR INVENTIONS M000037...

Отзывы: