The
"MINI-TRACER"
is capable of monitoring
BOTH WIRED and
WIRE-LESS
detector circuits at the same
time.
A
REMOTE PANIC BUTTON
option is built in as a standard feature.
The "MINI-TRACER"
will send an alarm/report whe
n
ever the following inputs are triggered:
- Any of the 6 wired active inputs.
- Any of the 6 wireless active inputs.
- Remote panic button.
- Supervisory signals such as:
- battery low in the wireless sensors. - low battery in the system.
-
arm / disarm. - battery restored in system.
- mains failure -
test transmission
- mains restored - Tamper & password change
- panic button
For complete application flexibility the six wired inputs may be programmed to send an alarm whenever one of the
following conditions occur:
- When the external circuit is opened (
Normally Closed circuit).
- When the external circuit is closed (
Normally Open circuit).
- Both when the external circuit is
Opened
or
Closed.
(In this case it is possible to program any of the circuits as an "alarm circuit" or a "door entry monitoring circuit").
- When the trigger condition remains for longer than 15 sec (slow detection).
For example
:
You may require that the particular circuit calls the control room both when an alarm occurs
and when it is restored, or that a particular circuit calls the control room both when a door is locked or unlocked.
The six wireless inputs work parallel to the wired inputs
and therefore share all the available
optional features such as:
- individual siren activation selection - individual "ENTRY/EXIT DELAY" selection
- individual "warning only" selection - individual "24 hrs" ready activation.
A great feature of the
‘MINI-TRACER"
is the fact that it is fully programmable to suit every possible
requirement.
You can for instance define 4 levels each containing a set of zones which you will most likely select in everyday
operation. You do not have to remember which set you normally arm or set to warning mode.
The
"MINI-TRACER
"
will memorize the four patterns for you and so when arming the system, automatically
step through these preset patterns allowing you to stop at the one you desire. These patterns may be changed
at will by the installer or by the customer using the two buttons on the hand-held remote control.
These preset levels can be
“Quick selected” . See “long-key” on table of key entries
ALL COMMANDS and INDICATIONS are performed / shown on up to 4 wall mounted Keypads / Display units .
The Key Pad / DISPLAY units can display the following information:
-
the wired/wireless sensor which caused the alarm. - the wired/wireless sensor which caused the warning signal.
- the perimeter beam which was activated. - system armed / disarmed indication.
- which zone is set to 24hrs, armed or on warning. - Entry / exit delay activated.
- mains failure has occurred. - system battery is only 80 % charged.
- system has triggered and the signal was sent to control room.
The GREEN numeric display shows the Sector which was activated on the perimeter beams.
The RED numeric display shows the type of transmission which was sent to the control room e.g.:-
- Numbers
1 to 6
indicating the alarm Zone which was triggered.
- The letter
"p"
indicating panic button activation.
- The letter "
t
" indicating test transmission.
- The letter "
b
" indicating battery low in one of the wireless sensors.
- The letter "
r
" indicating that the system had a reset.
- The letter “
h
” indicating a warning or a call facility.
- The letter “
u
” indicating the system is not programmed yet.
- The letter “
E
” indicating a tamper condition is present.
- The letter “
?
” indicates that the ID of the keypad is not the same as the ID of the Tracer
- The letter ”
j
” indicates wireless Radio Frequency blocking.
GENERAL INFORMATION