98
Mahr GmbH • Digimar 817 CLM
6.14.7 Delete menu / clear function
6.14.7.2 Default parameters
The following interface and basic adjustment
parameters are set to values defaulted at the
factory:
- Language
English
- Resolution
0.001 mm
- Plausibility factor
1.0
- Contacting speed
8 mm/s
- Standstill-time
1.0 s
- Temp. of height meas. inst
20 °C (68°F)
- Temperature of workpiece
20 °C (68°F)
- Coefficient of expansion
11.0
- Auto OFF time
5 minutes
- Background lit OFF
1 minute
- Printer: page length
58 lines (DIN A4)
- Tilting angle
90°
- Amplification factors
1.00
- Opto RS232
Duplex 4800 baud,
7 bits, even parity
The following data is deleted:
-
All values are saved in the measuring value
memory
-
Measuring value printout is no longer possible
-
Offset for the coordinate transformation
-
Zero points on part
1. <-_______
2. Temperature compensation
3. Probe calibration parameters
4. Function key F3
5. Enter password
6. Correction tables
7. Clear functions menu
8. Import language from USB
1. <-_______
2. Default parameter
3. Delete all programs
4. Delete all data files
5. Delete customer corrections
6. Delete production data tables
7. Delete all data
Are you sure?
1. Yes
2. No
6.14.6.8 Embedded service test
This menu is exclusively reserved Mahr-Service
personnel.
6.14.6.7 Service menu (reserved)
This menu is exclusively reserved Mahr-Service
personnel.
6.14.6.6 Perpendicularity correction table
Use an incremental probe to implement a
perpendicularity check for the customer correction
factor.
Please refer to chapter 10.4 Customer calibration
1. <-_______
2. Factory - corrections
3. Customer corrections
4. MK height correction
5. Print correction tab
6. Perpend. correction
7. Reserved
8. Embedded service tests
Service-password
1.000
1. <-_______
2. Factory - corrections
3. Customer corrections
4. MK height correction
5. Print correction tab
6. Perpend. correction
7. Reserved
8. Embedded service tests
Service-password
1.000
1. <-_______
2. Factory - corrections
3. Customer corrections
4. MK height correction
5. Print correction tab
6. Perpend. correction
7. Reserved
8. Embedded service tests
Содержание Digimar 817 CLM
Страница 8: ...8 Mahr GmbH Digimar 817 CLM 1 2 Unpacking 1 2 N I C K L M O P Q...
Страница 10: ...10 Mahr GmbH Digimar 817 CLM 5 350 mm 25 kg 600 mm 30 kg 1000 mm 35 kg...
Страница 11: ...11 Mahr GmbH Digimar 817 CLM 6 45 7 8 90...
Страница 12: ...12 Mahr GmbH Digimar 817 CLM 9 11 G H 10 12 13 M...
Страница 13: ...13 Mahr GmbH Digimar 817 CLM B 3x L M 19 17 18 P D E K N 14 15 16...
Страница 14: ...14 Mahr GmbH Digimar 817 CLM 100 240 V 50 60 Hz I 12 h 21 22 Euro US UK 20 23...
Страница 152: ......