81
RAIL PRESSURE DEVIATION
Sl No
DTC
Description
1
P1494
maximum negative rail pressure deviation with closed pressure control valve
exceeded
NORMAL OPERATION
The negative rail pressure deviation is within the limit
DTC Detecting Condition
Probable Causes
The negative rail pressure deviation is more against the expected
pressure specified in the map
Pressure control valve stuck
PCV supplied with power due
to electrical error
PCV reflex too high
LAMP STATUS
Engine check lamp continuously ON
FAULT REACTION
Engine low idle RPM set at 1200 .
The accelerator pedal will respond but the maximum RPM is set as 2000 with quantity limitations