13
Coolant
Temperature
sensor
P0118
Coolant temperature sensor voltage above upper limit
86
P0117
Coolant temperature sensor voltage below lower limit
EGR Actuator
P0403
Exhaust Gas Recirculation Actuator power stage no load
95
P0404
Exhaust Gas Recirculation Actuator power stage excess
temperature
P0406
Exhaust Gas Recirculation Actuator power stage short circuit to
battery
P0405
Exhaust Gas Recirculation Actuator power stage short circuit to
ground
Fan control Relay
P0480
Fan control open load error
103
P0691
Fan control Short circuit to ground
P0692
Fan control Short circuit to battery
P0607
Fan control over temperature error
Pre Supply Pump
P163F
Power stage of Pre supply pump no load
111
P1640
Power stage of Pre supply pump excess Temperature
P163D
Power stage of Pre supply pump short circuit to battery
P163E
Power stage of Pre supply pump short circuit to ground
Brake Switch
P1792
Brake signal not plausible
117
P1791
Brake signal received is defective
Clutch Switch
P0704
Main Clutch signal not plausible
125
ECU Main Relay
P121B
Main relay opens too early
133
P121A
Main relay sticky/ does not open in time
Battery
P563
Battery voltage above upper limit
138
P562
Battery voltage below lower limit