7.0 Using an AGS Module
SETUP
S
Set Stop Gen
Volts=
9.1
Status...
04 AGS Setup
04B Gen Run Time
OFF
04A Gen Run VDC
11.5 to 14.4
Set Stop Gen
AM-PM =
00:00
A
Set Stop Gen
Minute =
00:
00
P
Set Gen Run Time
OFF
Set Start Gen
AM-PM =
00:00
A
Set Stop Gen
Hour =
1
:00 P
Set Start Gen
Hour =
1
:00 A
Set Start Gen
Minute =
00:
00
A
METER
Status...
03 AGS Meters
03A AGS Status
Status...
03B DC Volts-AGS
0.0 VDC
03C Gen Run Time
0.0 Hours
03D AGS Temp
00F
03E Since GenRun
00 Days
Read Only displays
Set Start Gen
Volts=
OFF
Set Start Volts
Delay =
0 Sec
Set Stop Volts
Delay =
0 Sec
Set Start Gen
Volts=
11.5
Set Start Gen
Volts=
16.0
...
Set Start Volts
Delay =
120 Sec
Set Start Volts
Delay =
127 Min
...
Set Stop Gen
Volts=
14.4
S
S
S
S
Set Stop Volts
Delay =
120 Sec
Set Stop Volts
Delay =
127 Min
...
Set Gen Run Time
ON
S
Set Start Gen
Hour =
12
:00 A
...
Set Start Gen
Minute =
00:
59
A
...
Set Start Gen
AM-PM =
00:00
P
S
S
Set Stop Gen
Hour =
12
:00 P
Set Stop Gen
Minute =
00:
59
P
Set Stop Gen
AM-PM =
00:00
P
...
...
S
S
S
S
SETUP Menu continues on next page
S
Set Stop Gen
Volts=
Float
...
CTRL
03 Gen Control
OFF
Set Gen Control
OFF
Set Gen Control
ON
S
Set Gen Control
AUTO
...
...
...
...
AC In
Ready
Start Topoff
Fault Temp
Gen Cooldown
Start Amp
Start VDC
Fault Test
Gen Warm-up
Start Exercise
Gen Run Fault
Fault Time
Manual Run
Start SOC
Fault Amp
Fault Topoff
No Comm
Start Temp
Fault Exercise
Fault VDC
Off
Start Test
Fault MaxRn
Quiet Time
Start Time
Fault SOC
Available Statuses:
Start Gen Volts Ranges:
12v = 9.0-15.9 VDC;
24v = 18.0-32.0 VDC; 48v = 36.0-64.0 VDC
Stop Gen Volts Ranges:
12v = 9.1-16.0 VDC;
24v = 18.2-32.0 VDC; 48v = 36.4-64.0 VDC
Default:
OFF
7.6 ME-AGS-N Menu Map using the ME-ARC
Figure 7-2, ME-AGS-N Menu Maps using ARC Remote (Section 1)