MHR Radio Controller Instruction Manual
June 2017
Page 30 of 58
3.4 IO CONFIGURATION
IO Configuration:
Used to set input/output parameters. The lists of choices are:
•
PWM Frequency
This sets the Pulse Width Modulation frequency of the MHR outputs when either the
Current Compensated or Open Loop PWM output types are selected.
•
When current compensated (closed loop systems) is selected in the output type,
the MHR supports 75 to 1000Hz PWM frequencies.
•
When open loop PWM is selected in the output type, the MHR supports 33 to
1000Hz PWM frequencies.
•
For frequencies used outside of these ranges, please contact the factory.
To adjust the PWM frequency setting, select the PWM Frequency option and use the
and
buttons to cycle through each digit. Use the
and
buttons
to change the values of the digit selected. After the last digit is entered on the far
right side of the PWM Frequency screen, press
to return to the setup menu.
•
Output # (There will be one for each output available on the unit)
Use the
and
buttons to change the values of the Output # to the desired
number and press the
button to enter the configuration options for the output
selected.
NOTE: The output can be also configured as a digital input as well as three different output types.
Figure 13: Output Configuration Outputs
Содержание MHR
Страница 1: ...MHR Radio Controller June 2017 Part Number 195 50488 0100 R7 2017 Magnetek Material Handling...
Страница 21: ...MHR Radio Controller Instruction Manual June 2017 Page 20 of 58...
Страница 22: ...MHR Radio Controller Instruction Manual June 2017 Page 21 of 58...
Страница 23: ...MHR Radio Controller Instruction Manual June 2017 Page 22 of 58...
Страница 59: ...MHR Radio Controller Instruction Manual June 2017 Page 58 of 58 8 0 EU DECLARATION OF CONFORMITY...