MHR Radio Controller Instruction Manual
June 2017
Page 53 of 58
Alarm
Number
Alarm
Text
Cause of alarm
Effect of alarm
Recovery Action
44
S44. OUT
13 +VB
SHORT
When the output is
supposed to be at -
VBat, a voltage of 2V
or greater was seen
on the output. The
output was shut off to
prevent damage to
the hardware.
Output is shut off and will
not operate until the cause
is fixed and power to the
system is cycled
Determine the cause of the
short, fix the cause, and power
cycle the system
45
S45. OUT
14 +VB
SHORT
When the output is
supposed to be at -
VBat, a voltage of 2V
or greater was seen
on the output. The
output was shut off to
prevent damage to
the hardware.
Output is shut off and will
not operate until the cause
is fixed and power to the
system is cycled
Determine the cause of the
short, fix the cause, and power
cycle the system
46
S46. OUT
15 +VB
SHORT
When the output is
supposed to be at -
VBat, a voltage of 2V
or greater was seen
on the output. The
output was shut off to
prevent damage to
the hardware.
Output is shut off and will
not operate until the cause
is fixed and power to the
system is cycled
Determine the cause of the
short, fix the cause, and power
cycle the system
47
S47. OUT
16 +VB
SHORT
When the output is
supposed to be at -
VBat, a voltage of 2V
or greater was seen
on the output. The
output was shut off to
prevent damage to
the hardware.
Output is shut off and will
not operate until the cause
is fixed and power to the
system is cycled
Determine the cause of the
short, fix the cause, and power
cycle the system
48
S48. OUT
1 -VB
SHORT
When the output is
supposed to be at
+VBat, a voltage of
2V or less was seen
on the output. The
output was shut off to
prevent damage to
the hardware.
Output is shut off and will
not operate until the cause
is fixed and power to the
system is cycled
Determine the cause of the
short, fix the cause, and power
cycle the system
49
S49. OUT
2 -VB
SHORT
When the output is
supposed to be at
+VBat, a voltage of
2V or less was seen
on the output. The
output was shut off to
prevent damage to
the hardware.
Output is shut off and will
not operate until the cause
is fixed and power to the
system is cycled
Determine the cause of the
short, fix the cause, and power
cycle the system
Содержание MHR
Страница 1: ...MHR Radio Controller June 2017 Part Number 195 50488 0100 R7 2017 Magnetek Material Handling...
Страница 21: ...MHR Radio Controller Instruction Manual June 2017 Page 20 of 58...
Страница 22: ...MHR Radio Controller Instruction Manual June 2017 Page 21 of 58...
Страница 23: ...MHR Radio Controller Instruction Manual June 2017 Page 22 of 58...
Страница 59: ...MHR Radio Controller Instruction Manual June 2017 Page 58 of 58 8 0 EU DECLARATION OF CONFORMITY...