Page 32
6.35 Program LX Output (RX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “
→
” button to enter LX Output setting.
3) Press “
↑
” and “
↓
” button to scroll between OFF, Voltage, Current and PFM
output setting. Press “
→
” button to enter.
When Voltage is selected on step 3 above:
press “
↑
” and “
↓
” button to scroll
between Maximum, Neutral and Minimum value. Press “
→
” button to enter and
then “
↑
” and “
↓
” button to change voltage value. Press “
→
” button to go to the
next column to the right and press “
↑
” and “
↓
” button to change voltage value, and
so on. Press the “BACK” button to go back to the Maximum, Neutral and
Minimum selection.
When Current is selected on step 3 above:
press “
↑
” and “
↓
” button to scroll
between Maximum, Neutral and Minimum value. Press “
→
” button to enter and
then “
↑
” and “
↓
” button to change value. Press the “BACK” button to go back to
the Maximum, Neutral and Minimum selection.
When PFM is selected on step 3 above:
press “
↑
” and “
↓
” button to select
between 02K, 08K and 32K value. Press “
→
” button to enter and then “
↑
” and “
↓
”
button scroll between Maximum, Neutral and Minimum value. Press “
→
” button to
enter and then “
↑
” and “
↓
” button to set % range. Press the “BACK” button to go
back to the Maximum, Neutral and Minimum selection.
4) Exit Program LX Output by pressing the “BACK” button until the cursor is
shown next to “LX OUT”.
5) Press “
↑
” and “
↓
” button to scroll through other Flex 2JX settings.
6.36 Program LY Output (RX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “
→
” button to enter LY Output setting.
3) Press “
↑
” and “
↓
” button to scroll between OFF, Voltage, Current and PFM
output setting. Press “
→
” button to enter.
When Voltage is selected on step 3 above:
press “
↑
” and “
↓
” button to scroll
between Maximum, Neutral and Minimum value. Press “
→
” button to enter and
then “
↑
” and “
↓
” button to change voltage value. Press “
→
” button to go to the
next column to the right and press “
↑
” and “
↓
” button to change voltage value, and
so on. Press the “BACK” button to go back to the Maximum, Neutral and
Minimum selection.
When Current is selected on step 3 above:
press “
↑
” and “
↓
” button to scroll
between Maximum, Neutral and Minimum value. Press “
→
” button to enter and
then “
↑
” and “
↓
” button to change value. Press the “BACK” button to go back to
the Maximum, Neutral and Minimum selection.
When PFM is selected on step 3 above:
press “
↑
” and “
↓
” button to select
between 02K, 08K and 32K value. Press “
→
” button to enter and then “
↑
” and “
↓
”
button scroll between Maximum, Neutral and Minimum value. Press “
→
” button to
enter and then “
↑
” and “
↓
” button to set % range. Press the “BACK” button to go
back to the Maximum, Neutral and Minimum selection.
4) Exit Program LY Output by pressing the “BACK” button until the cursor is
shown next to “LY OUT”.
5) Press “
↑
” and “
↓
” button to scroll through other Flex 2JX settings.
Содержание FLEX EX
Страница 1: ...IR Programmer Instruction Manual V2 1 February 2018...
Страница 79: ...Page 78 11 Firmware Update 11 1 Install Software Install the provided software...
Страница 80: ...Page 79 11 2 Firmware Update 11 2 1 Set dipswitch position 1 to ON or 1 11 2 2 Plug in the USB cable...
Страница 81: ...Page 80 11 2 3 Please try the following if device can not be found when plug in the USB onto you computer...
Страница 82: ...Page 81 11 2 4 Open Flip 3 4 7...
Страница 83: ...Page 82 11 2 5 Select a target device 11 2 6 Select ATxmega256A3U...
Страница 84: ...Page 83 11 2 7 Select a communication medium 11 2 8 Select USB...
Страница 85: ...Page 84 11 2 9 Open USB 11 2 10 Load HEX file...
Страница 86: ...Page 85 11 2 11 Select HEX file downloaded from ARC website 11 2 12 Program target device memory...
Страница 120: ...Page 119 NO PB1 PB2 PB3 PB4 PB5 PB6 PB7 PB8 PB9 PB10 PB11 PB12 059 C 1 2 060 D 1 2 045 A 1 2 046 B 1 2 047 C 1 2 048 D12...