![background image](http://html1.mh-extra.com/html/magnetek/flex-ex/flex-ex_instruction-manual_3604703053.webp)
Page 52
9.4 Program System Frequency Range (TX & RX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “
→
” button to enter System Frequency Range setting.
3) Press “
↑
” and “
↓
” button to change frequency range.
4) Exit Program System Frequency Range by pressing the “BACK” button
until the cursor is shown next to “FREQ:”.
5) Press “
↑
” and “
↓
” button to scroll through other Flex EP-H settings.
9.5 Program System Channel (TX & RX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “
→
” button to enter System Channel setting.
3) Press “
↑
” and “
↓
” button to change system channel as a whole or…
4) Press “
→
” button to go to the digit on the left.
5) Press “
↑
” and “
↓
” button to change numeric value.
6) Press “
→
” button to go to the next digit to the right and repeat step 5.
7) Press BACK button to go back to step 3 or 4.
8) Exit Program System Channel by pressing the “BACK” button until the
cursor is shown next to “CHANNEL”.
9) Press “
↑
” and “
↓
” button to scroll through other Flex EP-H settings.
9.6 Program Transmitter Inactivity Timer (TX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “
→
” button to enter Transmitting Timer setting.
3) Press “
↑
” and “
↓
” button to select “__M__S” or “ON”.
4) When “ON” is selected, press “
→
” button and then “
↑
” and “
↓
” button to
select “+START” or “+ANY”.
5) When “__M__S” is selected, press “
→
” button to go to the digit on the far
left and press “
↑
” and “
↓
” button to select value.
6) Press “
→
” button to go to the next digit to the right and repeat step 5.
7) When programming “__M__S” is completed, press “
→
” button to enter
“+START”
or
“+ANY”
selection.
8) Press “
↑
” and “
↓
” button to select “+START” or “+ANY”.
9) Exit Program Transmitter Timer by pressing the “BACK” button until the
cursor is shown next to “TX TIMER”.
10) Press “
↑
” and “
↓
” button to scroll through other Flex EP-H settings.
Transmitter inactivity timer is for setting receiver main relays cutoff time when the transmitter
is not in operation for a certain period of time. When set to 5 minutes (05M), the receiver
main relays are deactivated at 5.0 minutes after last transmitter operation.
Select “ON” means the receiver main relays are activated at all time unless the STOP button
is pressed down, transmitter power turned off, or receiver power turned off (inactivity timer
disabled).
Select “+START” means after 5 minutes of transmitter inactivity you must rotate the power
keyswitch to START position to continue operation. Select “+ANY” means after 5 minutes of
transmitter inactivity press any pushbutton to continue operation.
Содержание FLEX EX
Страница 1: ...IR Programmer Instruction Manual V2 1 February 2018...
Страница 79: ...Page 78 11 Firmware Update 11 1 Install Software Install the provided software...
Страница 80: ...Page 79 11 2 Firmware Update 11 2 1 Set dipswitch position 1 to ON or 1 11 2 2 Plug in the USB cable...
Страница 81: ...Page 80 11 2 3 Please try the following if device can not be found when plug in the USB onto you computer...
Страница 82: ...Page 81 11 2 4 Open Flip 3 4 7...
Страница 83: ...Page 82 11 2 5 Select a target device 11 2 6 Select ATxmega256A3U...
Страница 84: ...Page 83 11 2 7 Select a communication medium 11 2 8 Select USB...
Страница 85: ...Page 84 11 2 9 Open USB 11 2 10 Load HEX file...
Страница 86: ...Page 85 11 2 11 Select HEX file downloaded from ARC website 11 2 12 Program target device memory...
Страница 120: ...Page 119 NO PB1 PB2 PB3 PB4 PB5 PB6 PB7 PB8 PB9 PB10 PB11 PB12 059 C 1 2 060 D 1 2 045 A 1 2 046 B 1 2 047 C 1 2 048 D12...