![background image](http://html1.mh-extra.com/html/magnetek/flex-ex/flex-ex_instruction-manual_3604703049.webp)
Page 48
8.12 Program Function Relay 2 / K26 Relay (RX)
1) Press “
→
” button to enter Function Relay 2 setting.
2) Press “
↑
” and “
↓
” button to scroll and select.
3) Exit Program Function Relay 2 by pressing the “BACK” button until the
cursor is shown next to “FUNC RLY2”.
4) Press “
↑
” and “
↓
” button to scroll through other Flex BASE settings.
--- : START
function
only.
LV
:
Function relay closes when receiver voltage is low.
ID
:
Function relay works simultaneously with all motion commands.
NORMAL
:
START fu AUX with normal momentary output.
TOGGLE
:
START fu AUX with toggled/latching output.
TOG&E
:
START fu AUX with toggled/latching output. The relay opens when
STOP button is pressed down and transmitter power off.
EXT
:
FUNCTION relay works simultaneously with the receiver MAIN relays.
TDM A+B
:
FUNCTION relay closes when selector switch is rotated to the A+B position
and opens when rotate to A or B positions (tandem monitoring output).
HORN
:
FUNCTION relay closes for up to 3 seconds when Start command is initiated at
transmitter power on and then becomes normal momentary outputs thereafter.
RS
:
For RS system, the function relay works simultaneously with the Select pushbutton.
8.13 Program Function Relay 3 / K30 Relay (RX)
1) Press “
→
” button to enter Function Relay 3 setting.
2) Press “
↑
” and “
↓
” button to scroll and select.
3) Exit Program Function Relay 3 by pressing the “BACK” button until the
cursor is shown next to “FUNC RLY3”.
4) Press “
↑
” and “
↓
” button to scroll through other Flex BASE settings.
--- : START
function
only.
LV
:
Function relay closes when receiver voltage is low.
ID
:
Function relay works simultaneously with all motion commands.
NORMAL
:
START fu AUX with normal momentary output.
TOGGLE
:
START fu AUX with toggled/latching output.
TOG&E
:
START fu AUX with toggled/latching output. The relay opens when
STOP button is pressed down and transmitter power off.
EXT
:
FUNCTION relay works simultaneously with the receiver MAIN relays.
TDM A+B
:
FUNCTION relay closes when selector switch is rotated to the A+B position
and opens when rotate to A or B positions (tandem monitoring output).
HORN
:
FUNCTION relay closes for up to 3 seconds when Start command is initiated at
transmitter power on and then becomes normal momentary outputs thereafter.
RS
:
For RS system, the function relay works simultaneously with the Select pushbutton.
Содержание FLEX EX
Страница 1: ...IR Programmer Instruction Manual V2 1 February 2018...
Страница 79: ...Page 78 11 Firmware Update 11 1 Install Software Install the provided software...
Страница 80: ...Page 79 11 2 Firmware Update 11 2 1 Set dipswitch position 1 to ON or 1 11 2 2 Plug in the USB cable...
Страница 81: ...Page 80 11 2 3 Please try the following if device can not be found when plug in the USB onto you computer...
Страница 82: ...Page 81 11 2 4 Open Flip 3 4 7...
Страница 83: ...Page 82 11 2 5 Select a target device 11 2 6 Select ATxmega256A3U...
Страница 84: ...Page 83 11 2 7 Select a communication medium 11 2 8 Select USB...
Страница 85: ...Page 84 11 2 9 Open USB 11 2 10 Load HEX file...
Страница 86: ...Page 85 11 2 11 Select HEX file downloaded from ARC website 11 2 12 Program target device memory...
Страница 120: ...Page 119 NO PB1 PB2 PB3 PB4 PB5 PB6 PB7 PB8 PB9 PB10 PB11 PB12 059 C 1 2 060 D 1 2 045 A 1 2 046 B 1 2 047 C 1 2 048 D12...