Page 61
9.23 Program PB5 Output Relay (RX)
1) Make sure the I-Chip is connected to the programmer.
2) Press “
→
” button to enter PB5 Output Relay setting.
3) Press “
→
” button and then “
↑
” and “
↓
” button to select “LOCK” or “UNLOCK”.
4) Press “BACK” button to go back to step 3.
5) Press “
↓
” button and then “
→
” button select PB5 Output Relay function.
6) Press “
↑
” and “
↓
” button to scroll and select.
7) Exit Program PB5 Output Relay by pressing the “BACK” button until the
cursor is shown next to “PB5 RLY”.
8) Press “
↑
” and “
↓
” button to scroll through other Flex EP-H settings.
UNLOCK Settings (PB5 and PB6 output relays not interlocked):
Select “NORMAL” the output relay becomes momentary contact.
Select “S” the output relay becomes momentary contact. Must press the green
START button together to work.
Select receiver “TOGGLE” the output relay becomes toggled contact.
Select receiver “TOGGLE&E” the output relay becomes toggled contact affected by the Stop
command (output relay opens when Stop button is pressed).
Select “PITCH” PB5 button becomes the “Pitch” function in Pitch & Catch Operation.
Select “PITCH&E” PB5 button becomes the “Pitch” function in Pitch & Catch Operation. When
Pitch command is initiated the receiver mains are disconnected.
Select “STOP” PB5 button becomes an auxiliary Stop function. Press to disconnect the receiver
mains and press START button to reconnect the receiver mains.
LOCK Settings (PB5 and PB6 output relays interlocked):
Select “NORMAL” both output relays become interlocking momentary contacts.
Select receiver “TOG/TOG” both output relays become interlocking toggled contacts.
Select receiver “TOG/TOG&E” both output relays become interlocking toggled contacts affected
by the Stop command (output relay opens when Stop button is pressed).
Select “ON/OFF” both output relays become interlocking On and Off contacts.
Select “ON/OFF+S” both output relays become interlocking On and Off contacts. Must press
the green START button along with the On or Off button to work.
Select “ON/OFF&E” both output relays become interlocking On and Off contacts affected by the
Stop command (output relay opens when Stop button is pressed).
Select “MAGNET” the two output relays become interlocking Magnet ON and OFF contacts.
Содержание FLEX EX
Страница 1: ...IR Programmer Instruction Manual V2 1 February 2018...
Страница 79: ...Page 78 11 Firmware Update 11 1 Install Software Install the provided software...
Страница 80: ...Page 79 11 2 Firmware Update 11 2 1 Set dipswitch position 1 to ON or 1 11 2 2 Plug in the USB cable...
Страница 81: ...Page 80 11 2 3 Please try the following if device can not be found when plug in the USB onto you computer...
Страница 82: ...Page 81 11 2 4 Open Flip 3 4 7...
Страница 83: ...Page 82 11 2 5 Select a target device 11 2 6 Select ATxmega256A3U...
Страница 84: ...Page 83 11 2 7 Select a communication medium 11 2 8 Select USB...
Страница 85: ...Page 84 11 2 9 Open USB 11 2 10 Load HEX file...
Страница 86: ...Page 85 11 2 11 Select HEX file downloaded from ARC website 11 2 12 Program target device memory...
Страница 120: ...Page 119 NO PB1 PB2 PB3 PB4 PB5 PB6 PB7 PB8 PB9 PB10 PB11 PB12 059 C 1 2 060 D 1 2 045 A 1 2 046 B 1 2 047 C 1 2 048 D12...