R e c h a r g e a b l e F l a s h l i g h t
MR Rev.1 8/03
421-000-438
20
CHARGER TESTS
Tests should be performed to determine the problem area prior to
replacing the circuit board.
CONVERTER TEST
METER READING
1. Dial is at V-20 volts.
2. Black probe is in the “COM” port.
3. Red probe is in the “V
Ω
mA” port.
CONVERTER
METER READING
1. Between 13.00 & 22.00 volts.
CIRCUIT BOARD TEST
METER SETTING
1. Set the dial at “A- 10A” Amps.
2. Black probe in “COM” port.
3. Red probe in “10ADC” port.
CONVERTER
LEAD REPLACEMENT
1. Place the leads, Red & Black into the pin
receptacles of the converter plug, (it does
not make a difference which lead goes into