background image

Constituent Parts

Product Outline

LCTX0005V2 to 0007V2

LCTX0002V2 to 0004V2

Precautions in use

Installation of the Floodlight

Don’t look straight at the LED. Your eyes might be impaired.

Carry out installation work in consideration of interference between the floodlight and structure.

1.

NB: 

*

Fig. 3

Fig.4

2. Loosen the two screws on the wire connection box cover and remove the cover.

3.

4.

(a)LCTX0005V2

0007V2

(b)LCTX0002V2

0004V2

5. Carry out Class D grounding  100

Ω 

or

 

below for the floodlight using the grounding terminal in the wire connection box.

 (recommended grounding terminal screw tightening torque: 1.3

1.5N

m).

Fig. 1 Interference between the floodlight and the structure  

Adjustment of the illuminating angle

1.

The product is a stationary floodlight. If it is not fixed for use, a fire, electric shock, burn or fall might result.

2. After adjustment of the illuminating angle, tighten the handles firmly (recommended tightening torque: 22

25 N

m).

LLPM00312

2

The LCTX00022V2 to LCTX0004V2 have

different seat shapes from the above but

their installation dimensions are the same as

those of the LCTX0005V2 to LCTX0007V2.

Pass a 3

wire cable with a final outside diameter of 10 to 14 mm (equivalent to or more than 600V 2PNCT (type 2 EP rubber

insulated

chloroprene cabtyre cable) through the fastening nut, connect it to the terminal block as shown in Fig. 4 and tighten the terminal block screw
firmly at a recommended torque (1.3

1.5 N

m). Fix the 3

wire cable with the cable retainer securely and tighten the cable retainer screw at a

recommended torque (1.3

1.5N

m) securely.

To adjust the illuminating angle, loosen the two handles with the floodlight supported by the angle adjusting grip securely (Fig. 2) and gently
adjust the illuminating angle. If the floodlight is not supported securely, it might suddenly turn, resulting in a damage or injury.

11E0000909A11

Installation manual

Rated input voltage

Voltage fluctuation range

Outdoor general application

Rain proof type

100

242V

Tighten the two screws on the wire connection box cover evenly at a recommended torque (1.3

1.5N

m) securely to prevent rainwater

infiltration. Also tighten the fastening nut securely to prevent rainwater infiltration.

Inadequate tightening might cause the floodlight to fall, resulting in an accident.

Insert the two M16 mounting bolts into the hole of the seat placed on the mounting surface of the building with the specified interval between
them (55 mm) as shown in Fig. 3 and firmly tighten each mounting bolt together with a plain washer, spring washer and M16 hexagonal nut at
a recommended torque (94

108 N

m). Inadequate tightening might cause the floodlight to fall and result in an injury.

LCTX0004V2

Wide angle

LCTX0005V2 to 0007V2

16kg

   

LCTX0002V2 to 0004V2

28kg

5000[K]

When the floodlight is installed on the ground and its

upward angle range is from 30 to 60 degrees, it cannot be

fixed due to the presence of the mounting bolts (M16). If the

mounting bolts interfere with rotation of the floodlight for

angle adjustment, adjust the illuminating angle before fixing

the floodlight.

If a floodlight pedestal is used, note that this floodlight is heavier than conventional (HID) floodlights and a conventional pedestal may
not be rigid enough and cause an accident such as a fall. If you are going to use a pedestal, consult us.

Narrow angle

Don’t use the floodlight in a place where it may be water

covered. The use in such a place might cause an electric leak, electric shock or

malfunction.

The color and brightness of LEDs fluctuate more largely than ordinary light sources such as candescent lamps and fluorescent lamps.
The color of light may vary with individual LEDs. Note that when the illumination distance is short, there may be uneven brightness or
color unevenness depending on the illuminated surface.

Gray metallic

Before installing the floodlight, confirm the range of motion of the floodlight as shown in Fig. 1(a) or 1(b). Paying attention to the
positional relation between the structure and the arm, take care that the floodlight does not contact the structure. An accidental
contact might cause a fire.

Be careful not to scratch the front cover of the floodlight. Scratching might cause damage, deterioration in watertightness or decline in
illuminance. If a crack is found in the front cover, let us know since it must be replaced immediately.

Application

Watertightness

Ambient temperature

Frequency

5

35

If the floodlight is used at a higher ambient temperature than 35°C or the LED is lit in a place exposed to direct sunlight, the internal
thermal fuse may be activated to turn off the LED. Though this is not a failure but a function to protect the electronic components, don’
t use the floodlight in such an environment.  A temperature rise might cause a fire or electrical failure or shorten the LED life.

Item

Light distribution

Weight

Color temperature

Finish color

The angle adjusting grip (Fig. 2) is intended to be used for illuminating angle adjustment after installation and should not be used to
carry the fitting. If it is used to carry the fitting, the fitting might fall and cause an injury.

Luminaire model

name

Suitable wire

3

wire cable with a final outside diameter of 10 to 14 mm

equivalent to or more than 600V 2PNCT (type 2 EP rubber

insulated chloroprene cabtyre cable)

Rated voltage ±6%

50 / 60Hz

LED Floodlight

LCTX0005V2

LCTX0007V2

LCTX0002V2

LCTX0006V2

LCTX0003V2

Medium angle

Fig. 2

Front cover

Wire connection

box

Wire connection box cover

Angle adjusting grip

Handle

Angle adjusting grip

Wire connection box cover

Front cover

Wire connection box

Handle

M16 hexagonal nut , Spring washer , Plain washer

M16 mounting bolt

Mount

Hole (18)

Floodlight installation dimensions

Terminal block screw

Terminal block

Grounding

terminal screw

Cable retainer

Cable retainer

screw

Fastening nut

3

wire cable

Outside diameter

Отзывы: