R e c h a r g e a b l e F l a s h l i g h t
MR Rev.1 8/03
9
421-000-438
B. LEAD PLACEMENT
1. The black lead is on the spring.
2. The red lead is on the outer
charging ring.
PROBLEM
Occasionally the CHARGER MODULE
(15) will stay in the BARREL (16) when it
is unscrewed. If this happens do the
following:
A. CHARGE MODULE METER SETTINGS
Meter reading is .005 – .764 mA. A bad
module will register .000 or 1 mA.
A. METER SETTINGS
Dial should be at 2k
Ω
ohms.
1. The black probe in the“COM” Port
2. The red probe in the “V_mA” port.
3. The meter should be reading “1.”