205
5. Apply dry compressed air (0.29 to 0.49 MPa) from the
inner side of the element along the fold. Blow compressed
air on the outside of the element along the grooves, and
re-blow the air on the inside.
6. Check the inside of the element by illuminating with a light
bulb and if any pores or thinned parts are found, replace
the element.
CAUTION
Do not tap or bump the element while cleaning it.
Avoid the use of an element if the groove, gasket, or
sealing is damaged.
Pack the unused elements and store them in a dry
place.
7. Set the cleaned outside element (4).
CAUTION
If the filter still clogs quickly despite having cleaned or
replaced outside element (4), replace the inside
element (5).
8. Match the match mark on dust cup (3) and the match mark
on the air cleaner body and fix with clip (2).
9. Press the button on the dust indicator (1) to return the red
piston.
Содержание CC423S-1
Страница 2: ......
Страница 8: ...vi This Page Intentionally Left Blank...
Страница 22: ...14 This Page Intentionally Left Blank...
Страница 56: ...48 SAFETY LABEL LOCATIONS 2 2...
Страница 59: ...51 24 Machine Mass 542 4773100 28 Working Radius Rated Total Load Chart 542 3582200...
Страница 60: ...52 30 Safe Operation 557 3494500 31 Operating the Moment Limiter 542 2250000...
Страница 194: ...186 This Page Intentionally Left Blank...
Страница 232: ...224...
Страница 248: ...240 This Page Intentionally Left Blank...
Страница 251: ...243 2 SPECIFICATION DIMENSIONAL DRAWING...
Страница 255: ...247 4 WORKING RADIUS LIFTING HEIGHT 4 Fall Wire Rope...
Страница 256: ...248 This Page Intentionally Left Blank...
Страница 262: ...254 3 MONITOR INDICATION 1 Searcher hook selector switch 2 Searcher hook position display...
Страница 276: ......
Страница 277: ......
Страница 278: ......