MAINTENANCE/SERVICE – M200 ENGINE
Form 169017
147
Issue – June 2008
7.10.4
Air Intake System
IMPORTANT
Do not run engine with air cleaner
disconnected or disassembled.
Engine intake air is drawn through a duct (A)
from the cooling box that pre-cleans the air, and
then through a dual element filter (B). The air
cleaner canister is equipped with a duct (C) that
removes dust continuously from the air cleaner
housing. The air cleaner is also equipped with a
restriction switch (D) which activates a warning
light on the CDM with an alarm when the
primary filter element requires cleaning.
NOTE
The warning light could activate when
operating in extremely dirty conditions, in
which case the filter element should be
cleaned. Under normal operating
conditions, filter servicing should be
performed at the specified interval. Refer
to Section 7.15, Maintenance Schedule.
7.10.4.1 Air Filter Servicing
DANGER
Stop engine and remove key from ignition
before leaving operator's seat for any
reason. A child or even a pet could engage
an idling machine.
a. Open engine compartment hood to highest
position.
b. Lift catch (E) on top of cap and rotate end cap
(F) counterclockwise until it stops and arrow (G)
lines up with unlock symbol on end cap. Pull off
the end cap.
c. Pull out the primary filter element (H) and
inspect as follows:
(continued next page)
D
C
B
A
F
E
G
H