OPERATOR’S STATION
Form # 169017
44
Issue – June 2008
(continued next page)
L1
D 1 3 0
||
C A B D I S P L A Y S E T U P ?
L2
C 1 4 0
||
N O / Y E S
C A L I B R A T E
S E N S O R S ?
L1
D 1 3 0 || D I S P L A Y L A N G U A G E ?
L2
C 1 4 0 || E N G L I S H
L2
C 1 4 0 || E S P A N O L
L1
D 1 3 0 || D I S P L A Y U N I T S ?
L2
C 1 4 0 || I M P E R I A L
L2
C 1 4 0 || M E T R I C
L1
D 1 3 0 || C D M B U Z Z E R V O L U M E
L2
C 1 4 0 ||
L1
D 1 3 0 || C D M B A C K L I G H T I N G
L2
C 1 4 0 ||
L1
D 1 3 0 || C D M C O N T R A S T
L2
C 1 4 0 ||
L1
D 1 3 0 || E X I T D I S P L A Y
S E T U P ?
L2
C 1 4 0 ||
N O
/ Y E S
D I S P L A Y
L A N G U A G E ?
L1
D 1 3 0
||
C A L I B R A T E S E N S O R S ?
L2
C 1 4 0
||
N O / Y E S
D I A G N O S T I C
M O D E ?
L1
D 1 3 0 || T O
C A L I B R A T E
S E L E C T
L2
C 1 4 0 || H E I G H T
/ T I L T / F L O A T
L1
D 1 3 0 || C A L I B R A T I N G H E I G H T
L2
C 1 4 0 || R A I S E H E A D E R
H O L D
L2
C 1 4 0 || R A I S E H E A D E R
D O N E
L1
D 1 3 0 || C A L I B R A T I N G H E I G H T
L2
C 1 4 0 || L O W E R H E A D E R
H O L D
L2
C 1 4 0 || H D R
H E I G H T
C O M P L E T E
L1
D 1 3 0 || T O
C A L I B R A T E
S E L E C T
L2
C 1 4 0 || H E I G H T
/ T I L T / F L O A T
L1
D 1 3 0 || C A L I B R A T I N G T I L T
L2
C 1 4 0 || E X T E N D T I L T
H O L D
L2
C 1 4 0 || E X T E N D T I L T
D O N E
L1
D 1 3 0 || C A L I B R A T I N G T I L T
L2
C 1 4 0 || R E T R A C T T I L T
H O L D
L2
C 1 4 0 || H D R T I L T
C O M P L E T E
L1
D 1 3 0 || T O
C A L I B R A T E
S E L E C T
L2
C 1 4 0 || H E I G H T
/ T I L T / F L O A T
L1
D 1 3 0 || C A L I B R A T I N G F L O A T
L2
C 1 4 0 || F L O A T ( + )
H O L D
L2
C 1 4 0 || F L O A T ( + )
D O N E
L1
D 1 3 0 || C A L I B R A T I N G F L O A T
L2
C 1 4 0 || F L O A T ( - )
H O L D
L2
C 1 4 0 || H D R F L O A T
C O M P L E T E
L1
D 1 3 0 || E X I T C A L I B R A T I O N ?
L2
C 1 4 0 ||
N O / Y E S
T O
C A L I B R A T E
S E L E C T
The operator can select any of the three items
requiring calibration.
If "NO" then jump to:
The operator can select any of the three items
requiring calibration.
When a function is activated, the display will
indicate the function being calibrated. HOLD will
flash until the system has completed reading in
the signal with the header fully raised.
DONE will flash and prompt the operator to
COMPLETE the sensor calibration by lowering
the header.
The "arrow" keys are used to select between
IMPERIAL or METRIC. The default value will be
displayed first.
The "arrow" keys are used to change the CDM
buzzer volume, CDM backlighting or the CDM
contrast, with the bar graph indicating the
relative level for each item. When "SELECT" is
pressed the program goes to the EXIT
DISPLAY SETUP? menu selection.
If "NO" then jump to:
When a function is activated, the display will
indicate the function being calibrated and HOLD
will flash until the system has completed reading
in the signal with the float fully raised.
DONE will flash and prompt the operator to
COMPLETE the sensor calibration by pressing
FLOAT (-).
If "NO" then jump to:
The operator can select any of the three items
requiring calibration.
When a function is activated, the display will
indicate the function being calibrated and HOLD
will flash until the system has completed reading
in the signal with the tilt fully extended.
DONE will flash and prompt the operator to
COMPLETE the sensor calibration by retracting
the tilt.
If "NO" then jump to:
Use the "arrow" keys to change the default
language. Pressing "SELECT" goes to the next