IMPORTANT SAFETY INSTRUCTIONS
Please read these instructions before using the Stinger Electric Insect Killer and keep for future reference.
1.
This product is equipped with a 2-prong plug to fit the proper type receptacles. To reduce the risk of electrical shock, only plug into a properly
installed outlet.
2.
Do not
insert fingers or any foreign objects into the unit while it is connected to an electrical outlet.
3.
Collected insects within the unit may contribute to fire. Clean dead insects from the unit frequently.
4.
Do not
clean this product with water, spray or any other liquids.
Do not
place where it can fall into water, or near flammable materials.
5.
For outdoor residential use only.
6.
Store product indoors when not in use – out of reach of children.
7.
Always disconnect plug before servicing, cleaning, changing bulbs and when not in use.
8.
Do not
abuse cord – never carry unit by cord. Unplug unit by pulling on the plug - not the cord. Keep cord away from heat, oil, or sharp edges.
9.
Extension cords used with this product must be marked with suffix letters “W-A” and with a tag stating “Suitable for Use with Outdoor Appliances”.
10.
Use only extension cords that have plug and receptacles that match the product plug. Replace or repair damaged cords.
11.
Electrical rating of the extension cord must be as great as the electrical rating of the product.
12.
There are devices available for retaining a connection between an extension cord and a power supply cord. Connections should be kept off the
ground and dry.
13. Do not
mount the unit on house, other buildings, on decks or near heat, gas, oil or other flammable materials.
HOW THE STINGER INSECT KILLER WORKS
The Stinger Electric Insect Killer is designed to attract and kill a wide range of flying insects. The
ultraviolet (UV) light given off by this unit is within the luminescent range proven effective to lure these
insects. Insects are attracted to the light and killed as they contact the electrically charged grid area.
Insects fall through the open base onto the ground. The outer protective cage helps prevent pets, birds,
butterflies, and children’s fingers from contacting the charged grids. This unit is for outdoor use only
and can withstand moderate rain. For best results, the unit should be installed in early spring and left on
throughout the season.
CHOOSING A LOCATION
(Figure 1)
When selecting a location, please remember that insects will be lured to the unit. Place the unit about 25 feet away
from the area intended for human activity. Position the insect killer between the source of insects (woods, water
supply, lowlands, etc.) and the area to be protected. Model BK100 will effectively cover a 1 acre area. Model
BK300 effectively covers 1 ½ acres.
INSTALLATION/OPERATION
1.
Unpack unit, save all packaging material for off-season storage.
DO NOT REST THE UNIT ON SURFACE WITHOUT
CONTINUING TO SUPPORT IT. It will not stand on its own.
2.
Select the proper location to hang the unit using the guidelines above. For Model BK300 use the bonus cord included
in the box to hang the unit.
3.
Hang the unit approximately 7 feet above the ground from a tree, mounting pole or other free standing object.
Never mount or hang the unit from a house or other building.
4.
Plug the cord into a compatible extension cord rated for outdoor use.
5.
The unit will be ON once it is connected to an electrical source. There is no separate ON/OFF switch.
Please allow up to 5 minutes for the bulb to light completely.
6.
Model BK300 has 2 settings – 24 Hour Operation and
™
Dusk to Dawn Operation.
a.
To select 24 Hour Operation, slide the grey button on the cap down so that it covers the sundown sensor.
The unit will remain ON 24 hours a day
(Figure 2)
.
b.
To select
™
Dusk to Dawn Operation, slide the grey button up, revealing the sundown sensor.
The unit will automatically turn ON at dusk, operate through the night, and turn OFF in the morning
(Figure 3)
.
7.
Using the available lure will add to the effectiveness of the unit by adding scent proven to attract more insects to the unit.
8.
It is recommended that this unit be put to use in early spring and left out until late fall to maximize effects.
9.
The unit is designed to withstand moderate rain but should be taken down and stored indoors during severe weather.
PRODUCT SPECIFICATIONS
Model
BK100 SERIES
BK300 SERIES
Area Coverage
1 acre
1 ½ acres
Replacement Bulb Type
B
A
Replacement Lure
NS16
NS16
Bulb Wattage
24W
24W
Device Wattage
50W
50W
Grid Voltage
4000V
4000V
Figure 1
DUSK-
24 HRS
Figure 3
DUSK-
24 HRS
Figure 2
TROUBLESHOOTING
Unit will not light, no apparent grid voltage
• Make sure the unit is plugged into working outlet
Unit will not light, grid has voltage
• Check bulb to make sure it is seated properly
• Replace bulb if necessary
Unit appears to be working properly but insect population does not seem reduced
•
Check surrounding area for sitting water, insects breed in these areas and should be eliminated at the source
• Allow more time. It will take some time for insects to find the unit and also for there to be an impact on their reproductive cycle
• Try moving the unit to another area of the yard. If you are in between the unit and the source of the insects, they will have to fly
by you to get to the unit and you may actually notice an increase in insects.
Unit is constantly arcing (sparking)
•
Clean the unit per the instructions in this manual • The unit will arc upon plug in and then stabilize. This is normal.
(Model BK-300 only) The unit does not come on during the daytime.
•
Check the sundown sensor which may be activated and only allows unit to operate dusk to dawn. See figures 2 and 3.
CHANGING BULBS
(Figure 5)
Only use Stinger replacement bulbs. Bulbs should be replaced annually to maintain optimal UV effectiveness. Even though the bulb’s light may be visible
to you, its ability to attract insects diminishes over time. If the bulb fails to light or the color of the light changes to yellow or orange it is time to replace
the bulb. See PRODUCT SPECIFICATIONS for bulb replacement type for your device.
Bulb contains mercury, dispose of properly.
INSTALLING THE NOSQUITO
®
MOSQUITO LURE
CLEANING
As the unit kills insects, most of the insect remains will be vaporized or fall down through the unit. Some debris may be left on the killing grid or may
accumulate in the base of the unit. This may reduce the effectiveness of the device. Check your device frequently and clean the unit regularly. The time in
between each cleaning will vary depending on your insect population.
1.
Unplug and remove entire unit from hanging position.
2.
Remove bulb from unit to avoid damage (see instructions above).
3.
Using a small brush or stick, gently remove any insect remains from the bottom of the bulb cap and enclosure.
4.
If available, compressed air may be used to clean the unit.
5.
Never use water to clean the unit. Water may damage the electrical components.
6.
Be very careful not to move or adjust the metal killing grid in any way.
7.
Once the unit is clean replace the bulb, return unit to hanging position and reconnect to power source.
Figure 4
Figure 5
A NOsquito
octenol lure by Stinger (NS16) is included with this unit. Research has shown that octenol is effective in attracting
many species of mosquitoes and biting flies. This lure has slow release properties and increases the effectiveness of
attracting insects to the unit. For best results, replace the lure every 30 days.
1.
Open the lure by peeling off the foil lid.
2.
All BK series models have a specially designed holder built into the base. Simply slide the lure into this holder with
the exposed octenol side facing into the device
(Figure 4)
. The lure should fit snugly and the tension tabs should hold it
securely in place.
3.
To remove – place thumb into recess and slide lure out. Discard appropriately in trash receptacle.
1.
Unplug and remove entire unit from hanging position.
2.
Turn the unit upside down.
DO NOT REST THE UNIT ON SURFACE WITHOUT CONTINUING TO SUPPORT IT.
It will not stand on its own.
3.
Use thumb to depress easy tab and open bulb cap.
4.
Pull old bulb up to remove.
5.
Insert new bulb making sure it is properly seated in the socket.
6.
Close the bulb cap by snapping it back into place.
7.
Place the unit back into the hanging position and plug into extension cord.
Note:
If unit fails to light after replacing bulb, unplug unit, take it down, remove the bulb and reseat it in the socket.