![background image](http://html.mh-extra.com/html/macdon/fd75/fd75_operators-manual_685691245.webp)
214323
227
Revision B
1003559
A
B
C
D
Figure 4.192: John Deere Combine Display
4.
Press DIAGNOSTIC button (D) on the monitor. DIA appears on the monitor.
5.
Press UP button (A) until EO1 appears on the monitor. This is the header adjustment setting.
6.
Press ENTER button (C).
7.
Press UP (A) or DOWN button (B) until 24 is displayed on the top portion of the monitor
—
this is the voltage reading
from the height sensor.
8.
Ensure that the header float is unlocked.
9.
Start the combine, and fully lower the feeder house to the ground.
NOTE:
You may need to hold the HEADER DOWN switch for a few seconds to ensure that the feeder house is fully lowered.
10. Check the sensor reading on the monitor.
11. Raise the header so that it is just off the ground and recheck the sensor reading.
12. If the sensor voltage is not within the low and high limits, or if the range between the low and high limits is
insufficient, refer to
Содержание FD75
Страница 8: ......
Страница 43: ...214323 25 Revision B Figure 2 1 Header Width 1018123 A B PRODUCT OVERVIEW ...
Страница 71: ...214323 53 Revision B For more information refer to Table 3 4 page 51 OPERATION ...
Страница 306: ......
Страница 360: ......
Страница 524: ......
Страница 538: ......