In this mode, after 3 seconds, the header fault parameter labels will appear on the EIP
’
s LCD.
NOTE:
The information which appears on the LCD is read-only.
Press OK (C) and CLEAR (D) buttons to scroll through the list of parameters. If there are no active fault codes, the EIP
’
s LCD
will display the message NO CODE.
When a parameter appears, its label is displayed for 3 seconds, after which its value is automatically displayed.
Pressing OK button (C) while the value is displayed will cause the EIP to advance to display the the next parameter
’
s label.
When a parameter label appears and OK button (C) is pressed before 3 seconds have elapsed, the parameter
’
s value will be
displayed.
Press AREA (E) to cycle through the options. When the message LEFT appears on the LCD, press OK button (C), and the
auto header height control (AHHC) voltage will appear on the display.
Press DIST button (F) to cycle back through the table.
Press CLEAR button (D) to exit the header diagnostics menu.
For instructions, refer to
4.2 Auto Header Height Control Sensor Operation, page 131
.