![MacDon FD75 Скачать руководство пользователя страница 177](http://html.mh-extra.com/html/macdon/fd75/fd75_operators-manual_685691177.webp)
214323
159
Revision B
4.7.5
Calibrating Auto Header Height Control
–
Case IH 7010/8010; 7120/8120/9120;
7230/8230/9230; 7240/8240/9240
–
Software Versions Above 28.00
The auto header height control (AHHC) sensor output must be calibrated for Case IH 7, 8, or 9 series combines with
software versions above 28.00, or the AHHC feature will not work properly.
For best performance of the auto header height control (AHHC) system, perform these procedures with the center-link set
to
D
. When the setup and calibration procedures are complete, adjust the center-link back to the desired header angle. For
instructions, refer to
NOTE:
Changes may have been made to the combine controls or the display since this document was published. Refer to the
combine operator
’
s manual for the most up-to-date information.
1.
Ensure that the center-link is set to
D
.
1009753
A
Figure 4.61: Case IH Combine Display
2.
Select TOOLBOX on the MAIN page and then select
HEADER SETUP.
3.
Locate the HEADER SUB TYPE field. It will be located on
either the HEAD 1 or HEAD 2 tab found at the bottom of
the display.
4.
Select 2000 (A).
1009754
A
B
Figure 4.62: Case IH Combine Display
5.
Locate the HEADER SENSORS and HEADER PRESSURE FLOAT
fields. They will be located on either the HEAD 1 or the
HEAD 2 tab found at the bottom of the display.
6.
Select ENABLE (A) in the HEADER SENSORS field.
7.
Select NO (B) in the HEADER PRESSURE FLOAT field.