Sensor Output Voltage Range
–
Combine Requirements
The auto header height control (AHHC) sensor output must be within a specific voltage range for each combine, or the
AHHC feature will not work properly.
Table 4.1 Sensor Voltage Limits
Combine
Low Voltage Limit
High Voltage Limit
Minimum Voltage
Range
Challenger
®
, Gleaner
®
A, Gleaner
®
S,
Massey Ferguson
®
0.7 V
4.3 V
2.5 V
Case IH 5088/6088/7088, 5130/6130/7130,
5140/6140/7140, 7010/8010, 7120/8120/
9120, and 7230/8230/9230
0.7 V
4.3 V
2.5 V
Case IH 2300/2500
3.0 V
7.0 V
4.0 V
Gleaner
®
R and S Series
0.7 V
4.3 V
2.5 V
John Deere 50, 60, 70, S, and T Series
0.7 V
4.3 V
2.5 V
CLAAS 500/600/700 Series
0.7 V
4.3 V
2.5 V
New Holland CR/CX - 5 V system
0.7 V
4.3 V
2.5 V
New Holland CR/CX - 10 V system
3.0 V
7.0 V
4.1
–
4.4 V
NOTE:
Some combine models do not support checking sensor output voltage from cab (early 23/2588 series, CLAAS 500/700
series). For these models, check output voltage manually. For instructions, refer to