214323
258
Revision B
1022780
A
Figure 4.261: John Deere S7 Display
–
Diagnostics Center
6.
Select AHC - SENSING (A). The AHC -
SENSING\DIAGNOSTICS page appears.
1022782
A
B
Figure 4.262: John Deere S7 Display
–
Checking Sensor
Voltage
7.
Select SENSOR tab (A) to view the sensor voltages. Center
header height sensor voltage (B) must be between 0.5 and
4.5 V, with at least 3 V of variation between 0 and 4 on the
float indicator box.
8.
If sensor voltage adjustment is required, refer to
Adjusting Voltage Limits, page 137
.
4.18.3
Calibrating Feeder House
–
John Deere S7 Series
Feeder house calibration must be done before header calibration.
DANGER
Ensure that all bystanders have cleared the area.
NOTE:
Changes may have been made to the combine controls or the display since this document was published. Refer to the
combine operator
’
s manual for the most up-to-date information.
NOTE:
For the best performance of the auto header height control (AHHC) system, perform the ground calibration with the
center-link set to
D
. When calibration is complete, adjust the center-link back to the desired header angle. For instructions,
refer to
Adjusting Header Angle from Combine, page 78
1.
Ensure the center-link is set to
D
.
2.
Rest the header on the down stops and unlock the adapter float.