![MacDon FD75 Скачать руководство пользователя страница 171](http://html.mh-extra.com/html/macdon/fd75/fd75_operators-manual_685691171.webp)
214323
153
Revision B
1003679
A
Figure 4.45: Case 8010 Combine Display
8.
Select LEFT SEN (A). The exact voltage is displayed. Raise
and lower the header to see the full range of voltage
readings.
1003680
Figure 4.46: Case 8010 Combine Display
9.
If the sensor voltage is not within the low and high limits,
or if the range between the low and high limits is
insufficient, then adjust the voltage limits. Refer to
Adjusting Voltage Limits, page 137
and Table
for instructions.
4.7.2
Setting Header Controls
–
Case IH 8010
The following procedure applies to Case IH 8010 combines without a shift button on the control handle.
1023783
A
Figure 4.47: Case Combine Controls
REEL FORE-AFT switches (A) also control header fore-aft tilt if
the header is equipped with the fore-aft tilt option. The
switches can be configured to allow the Operator to swap
between reel fore-aft and header fore-aft tilt.