54
If you’ve changed one of the listed parameter values, then the program will highl
ight the
changed value lines by
bold
. For sending the listed parameter values for the device
(regarding the
Selected
coloumn)
–
check the proper selection
–
push the
Write config
button at the bottom of the screen. At the end of the parameter sending, the device is
restarting by using the new settings.
Input settings
For
configuring the
input lines operation
open the
Input Settings
parameter group at the
Device Type
. Then the program will load the related parameters.
Here you can define values only for the input line nr. #1 and #2. The IO-expansion settings
will be listed later.
On the input lines of the device it is capable of generating Contact ID messages and
transmitting them by the ascending edge (L
→
H) and descending (H
→
L) edge. (The number
of the current input is signed here by’x’).
The length of the time frame can be configured by the
IDELAY
in 20 msec steps, which is
enabled
by default for the inputs to the ascending and descending edges without inverting in
an 500 msec time frame (here the delay value is 25 * 20msec).
The edges can be
enabled/disabled
by the
IxLHEN
(low-to-high) and
IxHLEN
(high-to-low)
parameters for every input line. The
direction
of the
edge detection
(ascending, descending)
can be reversed by the
IxINV
(as NO= Normal Open, NC=Normal Close) parameter.