9
Through the relay output a 2A - 120VAC or
2A - 24VDC voltage can be switched. When
activating the output, the
OUT LED
–
beside the output - indicates the active
(closed) position with the appropriate
color/light - during the operation.
ATTENTION
Always switch off power supply before the
wiring!
Check that the metal parts of the connected wires are not touch to each other!
Connecting the alarm line (ALARM line)
The alarm system can be connected to
the
ALR
input through a wire pair, thus it
will be able to forward its alarm signals
–
in Contact ID format
–
to the remote
dispatcher centre.
Connect the cable wire pair to the
ALR
title Alarm line’s terminal block (by sliding
the companion piece and inserting the
stripped wire pair, then fixing the screws).
When activating the output, the
ALR LED
–
beside the output - indicates the active (closed) position with the appropriate color/light -
during the operation.
Inserting the M2M Easy 2 IO board (optional)
The
M2M
Easy 2 Security Communicator
®
firmware can handle the operation of the
IO-
expander
board
(extra 6 pcs of inputs, 3pcs of outputs), whereas further parameters are
available in the device software and in the
EasyTerm
configuration tool.