FEEDER CABLE SECTION
Type “HO5RR-F”
230 V
3 x 2,5 mm
2
(*)
400 V 2N
5 x 1,5 mm
2
(*)
400 V 2N
4 x 1,5 mm
2
(*)
(*) – Connection with wall box connection
A
D
B
Fig. 10.1
1
5
4
3
2
L
1
PE
400 V 2N~
L
2
N
2
3
4
5
1
PE
L1
L2
N
2
3
4
5
1
N(L
2
)
PE
L1
1
5
4
3
2
L
1
N
(L
2
)
PE
230 V~
1
5
4
3
2
L
1
N
2
PE
400 V 2N~
L
2
N
1
2
3
4
5
1
PE
L1
L2
N2
N1
Fig. 10.2a
Fig. 10.2b
Fig. 10.2c
CONNECTING THE FEEDER CABLE
To connect the feeder cable to the cook-
er it is necessary to:
– Remove the two screws that hold
shield A behind the cooker.
– Open completely the cable clamp D.
– Position the U bolts onto terminal
block B (fig. 10.1) according to the
diagram in fig. 10.2a, 10.2b, 10.2c.
– Insert the feeder cable into the cable
clamp D. The supply cable must be of
a suitable size (see the section
“Feeder cable section”).
– Connect the phase and earth cables
to terminal B according figures 10.2a,
10.2b, 10.2c.
– Pull the feeder cable and block it with
the cable clamp D.
– Re-mount shield A.
N.B. The earth conductor must be left
about 3 cm longer than the others.
247