28
ENGLISH
Bypass
If a sensor is set to bypass, this sensor will not trigger any alarms anymore (does not
apply to tamper), as long as this value is set. Sensors, which cannot trigger alarms,
e.g. sirens, therefore do not react to the bypass function.
Disable tamper
If this function is active, the sensor will not trigger tamper alarms anymore (by e-mail,
text, siren wireless relay). However, a warning is still issued, if the XT2 is armed (and
in Home mode), until the system error is remedied or “Ignore system error” is ticked
via Control unit ->XT2 Status.
Example:
This function can be important, if a sensor/tamper contact disengages during longer
periods of absence and you do not want to receive a message concerning the tamper
contact failure every time the sensor status is checked.
Report
With this function active, Contact ID (if available) sends messages for this sensor. It
is not relevant to messages sent by e-mail and text.
Set/Unset
With this function, you can realize an arm/disarm function for window/door contacts
and wireless sensor inputs. The system is automatically armed or disarmed,
depending on whether the contact is closed or open.
Normally closed
The sensor is normally closed and arms the XT2 when opened.
Normally open
The sensor is normally open and arms the XT2 when closed.
CAUTION:
This function forces the immediate arming/disarming, irrespective of the set delay
times or possible system errors!
24 HR
If this function is active, the set alarm is triggered irrespective of the arming.
Disarm / Arm / Home 1 / Home 2 / Home 3 response
Set the required sensor action, if triggered, depending on the XT2 status.
No response
The control unit does not react at all, if the sensor is triggered.
Entry delay 1 / 2
The control unit starts the entry delay 1 or 2, if the sensor is triggered. If the system is
armed or in home mode and a sensor with the property “Entry delay 1 / 2” is
triggered, you can disarm the system within the pre-set time (see „Settings
Control
unit
Area settings
Delay 1/2 upon entry “). An event code (#131) is transmitted
during the entry delay. If the system is not disarmed during the delay, an alarm is
triggered.