128
ENGLISH
Status signal
If SW5 is set to ON, then the wireless sensor input transmits a status signal to the
control unit every 30 to 50 minutes. If the control unit does not receive the signal, it
will alert.
Put the wireless sensor input into operation:
To put the wireless sensor input into operation, proceed as follows:
1.
Insert the supplied batteries.
2.
Define the function with switch SW 1-4.
3.
Connect the contact to the required potential-free switch contact.
4.
Close the housing.
5.
Open the configuration page of the control unit, open the menu “Sensors”
“Add”
and click on Start.
6.
Press the test button of the wireless sensor input for about one second.
7.
The configuration page of the control unit should list the wireless sensor input.
8.
Add the wireless sensor input.
9.
You can test the signal strength in the Range menu. For that purpose, go to the
intended place of installation, press Range test
Start in the control unit menu
Sensors
Range and then press the Test button of the wireless sensor input. The
higher the indicated number the better the reception (1-9).
SW1
Door contact (DC-11C2)
ON
Activated (default)
OFF
Deactivated
SW2
Motion detector
ON
Activated
OFF
deactivated (default)
SW3
Smoke detector
ON
Activated
OFF
deactivated (Default)
SW4
Panic button
ON
Activated
OFF
Deactivated (default)
SW5
Status signal
ON
Activated (default for 868NF))
OFF
Deactivated (default for 868WF)
SW6
CON4 NO/NC
ON
Normally open (NO)
OFF
Normally closed (NC default)
SW
Shutter
ON
5 pulse / 10 sec
OFF
3 pulse / 10 sec (default)
SW8
Reserved