Add a tag to the tag reader:
1.
Start the installation mode by pressing the Arm or Disarm button and then
promptly setting switch 1 to ON. The Status LED starts flashing and one long
signal followed by two short signals sound.
2.
Press the Arm button once to start the tag learn mode. The Status LED lights up
for five seconds and one signal sounds.
3.
During this time, hold a tag in front of the tag reader panel. The Status LED
flashes fast three times and two signals sound, indicating the successful
integration of a tag in the tag reader.
4.
If you want to add several tags, hold them one after the other (at intervals of 5
seconds) in front of the tag reader re restart the entire process.
5.
Exit the installation mode of the tag reader by setting SW1 back to OFF.
Note:
With the new tag reader version (available since the beginning of 2015), you can
add an unlimited number of tags.
You can add a tag to an unlimited number of tag readers.
Only one signal indicates that this tag was already added.
Four signals indicate that the maximum tag number (6) is reached.
How to use the tag reader:
After having completed the tag reader installation as described above, you can use
the tag reader as follows:
1.
Arming/disarming
Press the Arm or Disarm button once to activate the tag reader.
2.
You have five seconds to hold a tag in front of the tag reader. If the tag is
recognized within this time, the control unit is armed or disarmed.
Caution:
If there are system errors available in the control unit when the system is armed,
repeat the arming process within 10 seconds, as otherwise the system remains
disarmed! Alternatively, you can activate the menu item “Forced arming”.
Factory settings:
1.
Open the housing. Remove the batteries, and then press any button to discharge
the remaining power.
2.
Set switch 2 to ON, reinsert the batteries. The tag reader signals the reset
(including the added tags) with an audio signal followed by two more signals. The
Status LED starts flashing. Set switch 2 to OFF again and close the housing.
3.
Delete the tag reader from the sensor list of the control unit.