![Lupus Electronics LUPUSEC-XT2 Скачать руководство пользователя страница 52](http://html1.mh-extra.com/html/lupus-electronics/lupusec-xt2/lupusec-xt2_manual_1950354052.webp)
52
ENGLISH
Note
:
The errors are listed in the menu “Control unit”
„XT2 status“.
o
Force:
The system is armed directly irrespective of errors in the system
(tamper, battery, open door, etc.).
Tamper alarm
o
Full Arm:
The sirens will sound in case of tamper alarm only in Full Arm mode.
They remain silent in all other modes (Disarm, Home 1-3).
o
Always:
The sirens will sound in case of tamper alarm in every mode.
Sensor check (supervisor)
Specify, whether the pain panel is to check the sensor status.
Time settings
Sensor check timer
The control unit receives status information from the sensors at regular intervals. If
the system does not receive information within this interval, an automatic log entry
will be created. Specify the intervals for the system to check the sensors here
.
Delay (1 and 2) upon entry
If someone enters the house with the XT2 armed, you may need a certain time to
deactivate the system with e.g. the XT keypad. You can specify this delay here. This
works only with sensors with the attribute “Arm response” (see chapter “Edit”), “Entry
Delay 1 or 2” is active. Sensors with the attribute “Burglar alarm instant” will always
trigger an alarm immediately.
Delay upon exit
If you arm the alarm system e.g. to leave the house, you may need a certain time to
leave the house and to close and lock the main door. You can specify this delay here.
After the delay has expired, the system will be armed.
Note:
In addition, “Ignore exit delay” must be ticked for each sensor (in every mode) in the
sensor list, which is not intended to trigger the alarm during the delay upon exit as
described in the Edit sensor menu.
Delay 1 / 2 upon entry (home modes)
If the home mode is active and a sensor with Home (1, 2, or 3) response set
Delay
upon entry 1 / 2 is triggered, the alarm is transmitted only after the time specified
here to give you the time to disarm the XT2.
Delay upon exit (home modes)
If the Home mode is activated e.g. via the keypad, you will usually need time to leave
the house or premises. You can set the delay before the alarm is triggered here.
Please observe the note under “Delay upon exit”.
Alarm duration
This item refers to the alarm duration of
all
integrated sirens. You can specify the
maximum alarm duration, if an alarm is triggered and the sirens are activated. If the
control unit is disarmed again, the acoustic alarm goes off.