Doorbell
The control unit rings (audio signal sounds only in the control unit itself, but not in
external sirens).
Burglar alarm Follow
This zone does not trigger the alarm, if an entry/exit zone has activated the “Entry
delay” before. An immediate alarm is triggered, if the entry delay was not activated
before. Use this sensor property e.g. for a motion detector in the entrance area,
which is directed to the entrance door (equipped with entry delay) (window/door
contact).
Burglar alarm Instant
The sensors triggers the alarm immediately.
Silent alarm
The sensor does not trigger the siren to sound, but sends an event code (#122) to
the security firm
”Silent alarm” and sends an e-mail (if not filtered out in the e-mail
menu).
Burglar alarm Outdoor
The sensor does not trigger the siren to sound, but sends the event code (#136) to
the security firm
”Outdoor Alarm” and sends an e-mail (if not filtered out in the e-
mail menu).
Execute home automation command
If the sensor changes its state, one of 16 home automation rules can be started,
which are defined in the Automation menu.
Home automation command (open)
If e.g. a window/door contact is open, one of 16 home automation rules can be
started, which are defined in the Automation menu.
Home automation command (close)
If e.g. a window/door contact is closed, one of 16 home automation rules can be
started, which are defined in the Automation menu.
Ignore exit delay
With this function ticked, the sensor will not react during the exit delay time of the
selected mode (Arm, Home 1-3). If the sensor is open and the control unit armed,
there is no warning signal upon changeover into the selected mode. This option
disables the warning of the sensor irrespective of the setting “Control unit”
“Arm
with failure”.
All areas
(sirens only)
If you want to assign an external siren to both areas, enable this option and make
sure that switch SW1 of the respective siren is set to ON! Then set switch SW1 back
to OFF.
Always on
(only PSS power supply units)
If you want to have a wireless socket or in-wall relay that is always on irrespective of
Содержание LUPUSEC-XT2
Страница 30: ...30 ENGLISH the status of the alarm system enable this option Afterwards activate the PSS device manually once ...
Страница 139: ...139 ENGLISH ...
Страница 145: ...145 ENGLISH Notes ...
Страница 146: ...146 ENGLISH Notes ...
Страница 147: ...147 ENGLISH Notes ...
Страница 148: ...148 ENGLISH Notes ...