Configuring the unit
DSLPipe/CellPipe Quick Setup
3-30
DSLPipe/CellPipe Quick Setup
2. Assume you are setting up ATM
over SDSL with Vpi set to 1 and Vci
set to 10. The Data Rate parameter is
set to 528 Kbps and you are using the
unit as CPE. Assume you will be
using a VC connection with IP rout-
ing.
Note:
The
*
to the left of a field
indicates that it is a required field.
You must fill in a value for the field.
Configure >
Chan Usage =
Leased/Unused
My Name=
* My Addr =
204.215.204.215
* Rem Name = ex2
* Rem Addr = 10.10.10.10
* Encaps = ATM
* Mux Type = ATM-VC
* Vpi = 1
* Vci = 10
* Route = IP
Bridge = No
Send Auth = N/A
Send PW = N/A
Recv Auth = N/A
Recv PW = N/A
Rate Mode = singlebaud
* SDSL Line Rate = 528000
* Unit Type = CPE
Table 3-11.Configuring the DSLPipe 50S as CPE
Scenario
DSL-Cell-50S configuration