Configuring the unit
DSLPipe/CellPipe Quick Setup
3-2
DSLPipe/CellPipe Quick Setup
The DSL-Cell-20A ships with a default configuration. The unit is set up to bridge
with ATM-LLC encapsulation. The VPI is set to 8 and the VCI is set to 35. If you
want to change these defaults, see “Configuring the DSL-Cell-20A” on page 3-8.
Configuring the DSLPipe units
All DSLPipe units ship with a default configuration. If you are setting up the
DSLPipe to bridge and use Frame Relay, you may not have to change the
configuration.You may be able to start using the DSLPipe after plugging in the cables.
See “Plug and Play capability” on page 3-3. Check with your service provider to see
if you need to change the configuration.
Note:
The CellPipes do not ship with a default configuration.
The default configuration uses the following settings:
The default configuration is an example of a connection profile. A DSLPipe
connection profile contains all the settings required to talk to a remote machine.
Table 3-1. Default DSLPipe configuration
Menu
Defaults
Configure
Route=None
Bridge=Yes
Ethernet > Connections
Station=DSLPipe
Active=Yes
Encaps=FR
Ethernet > Connections >
Encaps Options
FR Prof = DSLframe
DLCI=16
Ethernet > Frame Relay
Name=DSLframe
Active=Yes
FR Type=DTE
Link Mgmt=T1.617D