Configuring the unit
DSLPipe/CellPipe Quick Setup
DSLPipe/CellPipe Quick Setup
3-11
Downstream Speed: < Kbps>
Changing configuration information
Using the command-line interface of the DSL-Cell-20A, you can change the console
baud rate, and the VPI or VCI values. You can also change the ATM encapsulation
from LLC to VC multiplexing.
Changing the console baud rate
The default value at which you connect to the DSL-Cell-20A is 9600 bps. To change
this value, type the following:
lucent% set baudrate <bps> (
Press the Enter key
)
The baudrate can be any of the following: 9600 bps, 19200 bps, 38400 bps, 57600
bps, or 115200 bps.
Changing the VPI and VCI
The DSL-Cell-20A ships with the default VPI of 8 and the default VCI of 35. To
change the VPI or VCI, enter the following:
Table 3-3. Fields in the ADSL Status screen
Fields
Description
ADSL Chipset
Version
Version number of the chipset.
ANSI Version
ANSI version number.
Line Status
Up or Down. Up if the connection is active. Down if the
connection is inactive.
Upstream Speed
Speed from the DSL-Cell-20A unit to the CO site.
Downstream
Speed
Speed from the CO site to the DSL-Cell-20A unit.