Configuring the unit
DSLPipe/CellPipe Quick Setup
3-16
DSLPipe/CellPipe Quick Setup
Displaying SDSL rate
To display the SDSL line rate, type the following:
lucent% show sdsl stats
The current SDSL rate displays in the screen. The default is 2320 Kbps.
Changing configuration information
Using the command-line interface of the DSL-HSTB, you can change the console
baud rate, the Frame Relay DLCI, and the SDSL line rate. You can also choose to turn
off the SDSL rate Autohunt option.
Changing the console baud rate
The default value at which you connect to the DSL-HSTB unit is 9600 bps. To change
this value, type the following:
lucent% set baudrate <bps> (
Press the Enter key
)
The baudrate can be any of the following: 9600 bps, 19200 bps, 38400 bps, 57600
bps, or 115200 bps.
Changing the Frame Relay DLCI
The DSL-HSTB unit ships with the default DLCI of 16. To change the DLCI, enter
the following:
lucent% set fr dlci <number> (Press the Enter key)
The DLCI can be any number between 16 and 991. This command changes the DLCI
of the Frame Relay connection.
output octets
Number of bytes sent by the unit since the connection
became active.
Table 3-5. Frame Relay DLCI status screen
Fields
Description