![LS Industrial Systems MASTER-K80S Скачать руководство пользователя страница 94](http://html1.mh-extra.com/html/ls-industrial-systems/master-k80s/master-k80s_user-manual_1943827094.webp)
Chapter 7 Usage of Various Functions
7-17
7) pulse out operation explanation
Condition 1)
Set up as acceleration slop = 1, max. frequency = 1000, no of pulse out = 5000.
←
If as acceleration slop = 1, 1 pulse is output on the 1st step (velocity: 50pps).
Pulse velocity is 50pps, so time consuming is 20ms.
↑
2 pulses are output on the 2nd step (velocity: 100pps) and time consumes 20ms
→
By calculation in the same way, the time to reach to 1000pps is
20ms x (20-1) = 380ms, and the no. of output pulses are 1+2+3...+18+19 = 190 units.
↓
Decreasing velocity inclination is 1, thus 190 units of pulses are needed.
°
The no. of pulses in the uniform velocity region are 5000-190-190=4,620 units.
±
Whole spent time is 50,380ms
Time
velocity
Acceleration time:380ms
Accelerating pulses:190
Deceleration
20ms
50pps
Acceleration step : 19
Uniform velocity
Time :4,620ms
Pulses :4,620
Deceleration time :380ms
Decelerating pulses:190
1st step
2
nd
step
example: when acceleration is 1.