Chapter 7 Usage of Various Functions
7-
10
(5) 2-phase operation mode (4 Multiplication Operation : D4999 = h2014)
U/D : set automatically by the phase difference between A and B phase
PR : set by external PR input
Multiplication : 4 times
Ladder diagram
Time chart
HSC
EN
U/D PV 00100
PR SV 01000
MOV h2014 D4999
M000
A-phase pulse input
B-phase input (U/D)
Current value of HSC
10
14 16 18 20 22 24 25 23 21 19 17 15
12
15 19
23
24
20
16
11
17
21
25
22
18 14
13
F012
M001
M002