Chapter 7 Usage of Functions
7- 6 6
3) Reading A/T conversion value
A/T conversion value stores special data register as following.
Special data
register
Explanation remark
D4966
A/T conversion value of channel 1 stores
Expansion A/T module #1
D4967
A/T conversion value of channel 2 stores
Expansion A/T module #1
D4968
A/T conversion value of channel 3 stores
Expansion A/T module #1
D4969
A/T conversion value of channel 4 stores
Expansion A/T module #1
D4970
A/T conversion value of channel 1 stores
Expansion A/T module #2
D4971
A/T conversion value of channel 2 stores
Expansion A/T module #2
D4972
A/T conversion value of channel 3 stores
Expansion A/T module #2
D4973
A/T conversion value of channel 4 stores
Expansion A/T module #2
D4974
A/T conversion value of channel 1 stores
Expansion A/T module #3
D4975
A/T conversion value of channel 2 stores
Expansion A/T module #3
D4976
A/T conversion value of channel 3 stores
Expansion A/T module #3
D4977
A/T conversion value of channel 4 stores
Expansion A/T module #3
4) Program example
(1) Program explanation
Program which controls on-delay time of output contact point within 0 to 20 sec. By analog timer module.
(2) System configuration
Base Unit Analog timer module
(3) Program
A/T conversion data is moved D000 always
Содержание MASTER-K80S
Страница 27: ...Chapter 4 Names of Parts 4 4 1 3 30 points base unit 4 1 4 40 points base unit 4 1 5 60 points base unit...
Страница 66: ...Chapter 6 Input and Output Modules 6 3 30 point base unit 4 40 point base unit DC24V DC24V DC24V...
Страница 67: ...Chapter 6 Input and Output Modules 6 5 60 point base unit DC24V DC24V...
Страница 206: ...Chapter 8 Communication Function 8 63 You can see the frame list which is designated Click OK button...