10. Remote telephone operation 

User can dial telephone number of the control panel perform the operations: 
arm away/stay, disarm spot supervision and hearing alarm types. 

Dial telephone number of the control panel for more than ringing attempts 
set. The system will answer automatically and announce the user with a 
voice 'Di'. Then user presses '# + 4 digits password(user password operation 
password) + 1 operation digit + #', the control panel will operate 
corresponding commands. 6 operation digits, 1 means arm-away, 2 means 
arm-stay, 3 means disarm,4 means spot supervision, 5 means hearing 
current alarm voices, 0 means hang-up / stop dialing to alarm. 

For example, user password is 1234. To disarm the control panel, user can 
press '# 1 2 3 4 3 #' after switching on the system. If the operations is 
correct, 'Di' will be heard once. If the operations is incorrect, 'Di' will be heard 
twice. If password is wrong, user can input password and operate digit again 

 

 

 
 

5.2.2 Bell output terminals 

The maximal drive capacity of bell terminal (+BELL -) is 400mA /12VDC 

Connect the two power lines of the bell to 'BELL+' and 'BELL-' terminals 

When the system is powered up and initialized bell will chirp once, 
indicating it works normally .Setting the bell on/off and the chirping time 
can be programable with software 

 

5.2.3 Wired zone connection 

Each loop is connected to an end-of-line (EOL) resistor. For different 

detectors, modes of connection are shown as followed: 

When connecting N.C. detector, connection mode: 

without inputting '#' in advance. The control panel will hang up if password is 
input incorrectly three times or user does not press any key in 30 seconds 
during the operations. 

When alarming, the control panel dial user telephone, if there is no voice 

Zone 

 

N.C. Detector 

after receiving the telephone or user unwilling to wait, pressing any key (key 
'5' recommended), the control panel will play voice information immediately. 
Alarm information order is user address record then the alarm type voice. 
The system will circulate play the alarm voice information. 

Note: 1.Do not press any keys during voices 'Di' or messages can not be 
received correctly. Do not press any key when the system is in voice alarm 
status. 2.If user hang up the telephone without any operation the control 
panel will dial user telephone repeatedly. 

 

10.1 Telephone disarm 

After picking up the telephone press '# + 4digits password(user 

password, operation password) + 3 + # ' to disarm, for example, if user 
password is 1234, press '#12343#'. 
When the control panel dials to alarm, user can press 3 to disarm after 
hearing alarm voice. 

 

10.2 Telephone arm-away 

After picking up the telephone, press '# +4digits password(user 

password, operation password) + 1 + #' to arm, When alarm occurs, user 
has to disarm first and then arm the system again. For example, if user 
password is 1234, press '#12343#' and then press '1#' to arm after 
hearing prompt voices. 
When the control panel dials to alarm, user can press 3 to disarm and 
then press 1 to arm after hearing alarm voice. 

 

-28- 

 

Figure 5 N.C. Detector 

 
 

When connecting N.O. detector, connection mode: 

 

Zone 

 

N.O. Detector 

 

 

Figure 6 N.O. Detector 

 

5.2.4 Telephone line connection 

Connect telephone line to 'LINE_IN' interface of the control panel 
(Refer to the figure 3) 

Connect telephone or facsimile machine to 'LINE_OUT' interface of the 
controller panel, ensuring no effect on telephone(Refer to the figure 3) 

Under the telephone line monitoring status, the control panel will alarm 
when the telephone line trouble. 'T' flashes per second in lower right 
corner of LCD, buzzer chirps for 1 minute. After disarmed buzzer off and 
'T' flashes on LCD 

 

-5-

Содержание LHD8001

Страница 1: ...MGE Entreprise Av Kouwait 8050 Hammamet Tunisie Tel 1 00216 72 278 663 Tel 2 00216 22 645 120 Email manager mge security com www mge security com INSTALLATION MANUAL LHD8001 SECURITY SYSTEM...

Страница 2: ...2 Remote Controller 2 3 Wireless Passive Infrared Detector 1 4 Wireless Magnetic Switch 1 5 Power adapter 1 6 Installation manual 1 7 Telephone line 1 8 Accessories bag 1 Zone number Installation pos...

Страница 3: ...assignment 7 1 Zone type 10 10 24 Zone bypass 25 Zone reactivate 26 Voice recording 27 Record playing 28 Viewing event log 65 66 70 71 80 X X 0 X X X 01 16 16 wireless zones X 21 24 4 wired zones No b...

Страница 4: ...All remote controllers canceling 9 3 34 Zone type initialization 9 3 35 System default restoring 10 Remote telephone operation 10 1 Telephone disarm 10 2 Telephone arm away 27 27 27 27 28 28 28 4 Oper...

Страница 5: ...nect to 2 2K resistance 2 Control device Remote controller Keypad Local or remote telephone system 3 Wireless frequency 315MHz 433MHz 868 MHz optional Communication protocol ADEMCO 4 1 and Contact ID...

Страница 6: ...s The station will take corresponding actions after receiving the alarm Entry delay A period for user to enter detection area activate the delay zone and disarm before the system alarms During the per...

Страница 7: ...rm Arm 11 21 15 Remote controller arm disarm Disarm arm operation by using the type and of the detector Confirm the installation position and wiring direction according to the specific condition Make...

Страница 8: ...y is well charged it can supply the system with power more than 14 hours low battery it can supply power more than 1 5 hours Low battery power indi cator f lashe s fast when AC power is low voltage po...

Страница 9: ...telephone if there is no voice Zone N C Detector after receiving the telephone or user unwilling to wait pressing any key key 5 recommended the control panel will play voice information immediately A...

Страница 10: ...rs are canceled Please use standby battery to ensure the control panel can work normally when AC power failure 9 3 33 All remote controllers canceling Enter 940 Fix the control panel to the wall by sc...

Страница 11: ...ftware version of CPU are not identical LCD displays Version vary and buzzer beeps user can cancel the alarm by disarm command In this condition it is better to inform the supplier in time This operat...

Страница 12: ...play Arm away Year Month Day Hour Minute Indicating the system is in arm away status the present time is Year Month Date Hour Minute or the system is in arm stay or disarm status The corresponding dis...

Страница 13: ...is in zone alarm status and the zone be triggered again the Operations PROG user password 66 XX system will prompt zone alarm only but entry delay Parameters definition XX means reactive bypassed zone...

Страница 14: ...avoid influence from wireless clutter wave During the code learn operation only the key is valid press this key to exit the code learn operation status 9 3 21 Wireless zone detector canceling Enter 6...

Страница 15: ...etector Functions Enroll wireless detectors as required For example Enroll NO 03 wireless zone detector displays Arming press PROG user password 61 03 The keypad buzzer will stop after exit delay expi...

Страница 16: ...e If user wants to cancel some set disarming time set YYYY as 8888 For example Set 08 00 and 22 00 as disarm time press PROG user password 36 1 0800 36 2 2200 Program press user password or operation...

Страница 17: ...32 10 alarm indicator on buzzer chirps continually LCD displays 9 3 15 Date setting Enter 33 XXXX ZONE 17 Panic Year Month Day Hour Minute Operations PROG user password 33 XXXX Parameters definition X...

Страница 18: ...no delay XX 01 10 seconds XX 02 20 seconds Following the cursor input the commands If the input digits are incorrectly press key to delete them then press key to confirm If the XX 10 100 seconds inpu...

Страница 19: ...tions The system can be set 6 groups of alarm telephone number NO 9 3 10 Relay output type setting Enter 28 X 1 is for the center stations If alarm happens the system will call center stations and sen...

Страница 20: ...assword user should ensure its safety and reliability Restore password in factory default setting Hardware restores factory 9 3 6 Bell ON OFF setting Enter 24 X default setting There is a jumper CB400...

Отзывы: