![LONGHORN LHD8001 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/longhorn/lhd8001/lhd8001_installation-manual_1938629012.webp)
6.2 Power up the system
9.3.27 Record playing
Enter: 71 X
Check all wiring are correct
Operation: (PROG X
#)
71 x #
Switch on AC power or turn on the standby battery, buzzer will beep twice;
keypad backlighting
and power indicator will be on. Keypad begins to
initialize and then buzzer beeps continuously, LCD displays:
Initialize...
LCD circularly displays the status information, buzzer beeps twice per
minute. Buzzer steady beeps to indicate the initialize successful, LCD
displays the status information. The system begins working .If the system
works normally, it will take two seconds for initialization. If this process
takes more than eight seconds, LCD displays 'Communication Error!' and
buzzer chirps per second. The failure cause is bad wiring between the
control panel and keypad.
Parameters setting:
X=1~8 specified alarm voice, X=9 user address record
playing
X=1: enter/exit alarm
X=2: active alarm
X=3: perimeter alarm
X=4: panic alarm
X=5: fire alarm
X=6: gas alarm
X=7: anti-tamper alarm
X=8: duress alarm
X=9: (voice recorded by user.)
Function:
User can check voice effect.
6.3 System initialize successful
Initialize successful, LCD will display:
Arm-away
Year-Month-Day Hour: Minute
Indicating the system is in arm-away status, the present time is 'Year-
Month-Date Hour: Minute' or the system is in arm-stay or disarm status.
The corresponding display is the status when the system is closed last
time.
Version vary!
Year-Month-Day Hour: Minute
If LCD displays 'Version vary!' and buzzer beeps, that indicate user can
For example:
(PROG user password #) 719
While playing, LCD displays:
Playing...
04 sec
After playing, LCD displays:
Input Command
9.3.28 Viewing event log
#
Enter: 80 XX
clean CPU (U1
U201
U402) with different software version. Cleaning
Operations: (PROG
user password
#)
80
XX
#
the alarm voice and the display by disarm command. In this status please
contact with the manufacture or the supplier. Refer to the appendix 1 for
inquiring software version.
6.4 Alarm
The alarm can be classified as two types: zone alarm and system trouble.
-8-
Parameters definition:
XX=01~40 event logs.
Functions:
The system stores 40 event logs, which can be viewed by user
at any time. The system logs alarm in zones, but system trouble for AC
power failure, low battery, telephone line trouble, etc.
Note:
XX=01~40 is event number in time order. The latest event number is
01, the rest are numbered in this way. When the fortieth even is logged, the
latest event log replace the oldest event log. After inputting
-25-