2. If the system is in 'Arm-away' status and no zone alarms, press the
'STAY' key on control panel, input password to enter arm-stay status or
press the 'Arm-stay' key on remote controller to enter the arm-stay
X minute (24 hours), default is 8888.
Functions:
The system can set 3 groups arm time. If user wants to cancel
some set arm time, set YYYY as 8888.
status directly ,buzzer chirps once ,armed indicator flashes.
3. When the system in zone alarm status, press the 'STAY' key on the
control panel or 'Arm-stay' key on the remote controller, LCD displays:
For example:
Set 08:00 and 22:00 as arm time.
press: (PROG user password #) 35 1
#
0800
#
35
2
2200
Can't arm
Please disarm
Note:
Before performing the functions above, please set 'Auto-arm/auto-
disarm selection' first. Refer to 9.3.7
4. When the system is in arm- stay status, buzzer chirps once.
9.3.18 Auto-disarm time setting
Enter: 36 X YYYY
8.3 Disarm
1. Disarm without reserving the alarm status information press: the 'DISARM'
key on the control panel, LCD displays:
Input Password
Operations: (PROG user password #) 36 X YYYY #
Parameters definition:
X means 1~3 groups disarming time. YYYY means
X hour X minute (24 hours), default is 8888.
Functions:
The system can set 3 groups disarm time. If user wants to
cancel some set disarming time, set YYYY as 8888.
For example:
Set 08:00 and 22:00 as disarm time,
press: (PROG
user password
#)
36
1
0800
#
36
2
2200
Program: press user password or operation password
'0'
'#' . Armed
#
indicator off, buzzer chirps once, the system is disarmed, LCD displays:
Disarmed
Note:
Before performing the functions above, please set 'Auto-arm/auto-
disarm selection' first, refer to 9.3.7. Auto-arm/disarm time must be different
because they can't be operated at the same time.
Year-Month-Day Hour: Minute
9.3.19 Zone definitions
Enter: 40 XX Y
2. Disarm with reserving alarm status information: press the function key
'DISARM' on the control panel, LCD displays:
Input Password
If there is no alarm, input user password or operation password then
press '#' confirm. Armed indicator off, buzzer chirps once, the system is
disarmed, LCD displays:
Disarmed
Year-Month-Day Hour: Minute
If the system is in zone alarm status, after disarmed the system, armed
indicator off, buzzer chirps once, LCD displays zone alarm information
but the system is still in disarm status. User can disarm again to clean the
alarm information.
-12-
Operations: (PROG user password #) 40 XX Y #
Parameters definition:
XX means wired/wireless zone number.
XX=01~16 (16 wireless zones);
XX=21~24 (4 wired zones);
Y=1, entry/exit zone;
Y=2, active zone;
Y=3, perimeter zone;
Y=4, panic zone;
Y=5, fire zone;
Y=6, gas zone;
Y=7, anti-tamper zone;
Y=8, duress zone;
-21-