commands successfully, alarm time, alarm type, corresponding zone type
and zone number display on LCD. Press '6' key to turn up '9' key to turn down
for continually inquiring. Flip requirement press '#' then press '80 XX #'
until the last inquiring finished.
6. Operation
6.1 Control panel composition
For example:
Viewing the No.5 event record input password
80
05
#,
LCD
Record monitor microphone
LCD displays alarm time alarm zone and alarm type.
Armed indicator
Year-Month-Day Hour: Minute
ZONE 17 Panic
Power indicator
Alarm indicator
Key
Viewing the No.9 event record, press '#' first then input 80
09
# If the
Horn
event record is null, LCD displays:
Figure 9
Program Fail!
1. LCD:
Displays time and system working status
Provides function indicator lights and word descriptions for zone status
'T' will flash in the lower right corner of LCD when telephone line trouble
9.3.29 Software version inquiring
Operations: (PROG user password #) 88
#
Enter: 88 X
2. Armed indicator: indicator on (arm-away)
indicator flashes (arm-stay)
Parameters definition:
X=1 inquire software version U1
X=2 inquire software version U201
X=3 inquire software version U402
Function:
When power up the system, if these three software version of
CPU are not identical, LCD displays 'Version vary!' and buzzer beeps, user
can cancel the alarm by disarm command. In this condition it is better to
inform the supplier in time. This operation can inquire software versions of
the th ree CPU. For example: inquire software version U1: (PROG user
indicator off (disarmed)
3. Power indicator: indicator flashes quickly indicate low-battery; indicator
flashes slowly indicate AC power low-voltage; indica tor
on indicate standby battery and AC power are in
normal working status. While power failure, buzzer
chirps one minute.
4. Alarm indicator : indicator on when zone alarming; indicator flashes when
dialing the center stations.
password #) 88
1
#
5. Horn
: Voice guide the operation.
6. Record monitor microphone: spot supervision or used for recording.
The U1 CPU
version V 1.1
Indicate present U1 software version is V1.1
-26-
7. Key
Four function keys: AWAY, STAY, DISARM, and PROG keys. The PROG
key is a compound key and its other function is for panic
Digit key, '*' key and '#' key are used in programming and relevant
operations. '*' key is used to cancel the last operation; '#' key is used
to confirm the input; '6' and '9' are used to turn pages while inquiring
events log or many zones alarm at the same time
Note:
Pressing any keys, buzzer sounds 'Di' and keypad backlighting on. If
no key be pressed within 30 seconds the keypad backlighting off.
-7-