The keyboard
XX= 02 (2 minutes)
has been locked!
XX =10 (10 minutes)
Note:
The keypad will be locked with fail operation. The system unlock
automatically under the following status: 1. Restarting the system; 2.
XX =20 (20 minutes)
Waiting half an hour.
XX =30 (30 minutes)
9.2 Operation step
Make sure the system in disarmed status otherwise LCD displays:
The factory default setting is XX= 10 (10 minutes)
Function:
Buzzer and bell chirp times adjustment.
Can't program
Please disarm!
9.3.12 Exit delay time adjustment
Enter: 30XX
Operations: (PROG
user password
#)
30 XX #
User disarms first then input: PROG +user password (not the operation
password) + #, the control panel enter programming status, LCD displays:
Input Command
Parameters definition:
XX=00~30, indicating time, unit is 10 seconds,
delay time is among 0~300 seconds.
XX=00 (no delay)
XX=01 (10 seconds)
XX=02 (20 seconds)
Following the cursor, input the commands. If the input digits are
incorrectly, press '*' key to delete them then press '#' key to confirm. If the
XX=10 (100 seconds)
input command is correct, the control panel chirps twice, LCD displays:
XX=20 ( 200 seconds)
Input Command
XX=30 (300 seconds)
Input the command to set the program, if the command is incorrect,
control panel will chirp five times, LCD displays:
The factory setting is XX=10 (100 seconds)
Function:
The system exit delay time adjustment.
Command Error!
9.3.13 Entry delay time adjustment
Enter: 31 XX
Then input commands without password. If the command is correct, the
control panel chirps five times, LCD displays:
Program Fail!
That indicates the program is correct but the control panel can not carry
out the command, user should input it again.
-14-
Operations: (PROG user password #) 31 XX #
Parameters setting:
XX=00~30, unit is 10 seconds, delay time is among
0~300 seconds.
XX=00 (no delay)
XX=01 (10 seconds)
XX=02 (20 seconds)
-19-