Zone
type
Valid or
not when
disarm
Valid or
not when
away
Valid or
not when
stay
Exit
delay
Entry
delay
Sound and
flash
Mounted
position or
detector
Type
number
Entry/Exit
zone
Invalid
Valid
Valid
Yes
Yes
Yes
Gate
01
Active
zone
Invalid
Valid
Invalid
Yes
Yes
Yes
Indoor
02
Perimeter
zone
Invalid
Valid
Valid
No
No
Yes
Veranda
Window
03
Panic
zone
Valid
Valid
Valid
No
No
Yes
Panic
Button
04
Fire
zone
Valid
Valid
Valid
No
No
Yes
Fire
Detector
05
Gas
zone
Valid
Valid
Valid
No
No
Yes
Gas
Detector
06
Anti-tampe
r
zone
Valid
Valid
Valid
No
No
Yes
Anti-tamper
Device
07
Duress
zone
Valid
Valid
Valid
No
No
No
Emergency
Button
08
Zone type
LCD display
Type number
Entry/Exit zone
Entry Exit
01
Active zone
Active
02
Perimeter zone
Perimeter
03
Panic zone
Panic
04
Fire zone
Fire
05
Gas zone
Gas
06
Anti-tamper zone
Tamper
07
Duress zone
Duress
08
7. Zone type and zone assignment
7.1 Zone type
other remote controller. Changing the code learn to solve the above problem.
If the problem is the above reasons, checking the detector and make sure its
carrier frequency is different from the control panel.
Note:
After inputting command, user has to trigger a wireless detector within
1 minute, otherwise the system can't enroll the wireless detector. Moreover,
user had better trigger a wireless detector as soon as possible to avoid
influence from wireless clutter wave. During the code learn operation, only
the '*' key is valid, press this key to exit the code learn operation status.
9.3.21 Wireless zone detector canceling
Enter: 62 XX
Operations: (PROG
user password
#) 62
XX
#
Parameters definition:
XX=01~16, indicating zone number of wireless
detector.
Functions:
Cancel wireless detectors as required.
For example:
Cancel NO.03 detector in wireless zones
7.2 Zone assignment
press: (PROG
user password
#)
62
03
#
Wireless zone: 01~16
Wired zone: 21~24
9.3.22 Enroll remote controller
Enter: 63 X
Panic zone: 17
Duress zone: 18
Operations: (PROG
user password
#)
63
X #
Anti-tamper: 30
7.3 Zone type displaying
Parameters definition:
X=1~5, number of remote controller.
Functions:
The system can enroll 5 remote controllers at most. After
inputting command, press any key of remote controller towards the control
panel until buzzer chirps once. It indicate the system enroll the remote
controller successful. Refer to 9.3.20.
9.3.23 Remote controller canceling
Enter: 64 X
Operations: (PROG
user password #) 64
X #
Parameters definition:
X=1~5, number of wireless remote controller.
Functions:
After canceling some remote controller it have no effect on the
system.
9.3.24 Zone bypass
Enter: 65 XX
8 Function key operation
Operations: (PROG user password #) 65 XX
Parameters definition:
XX means zone bypass number.
#
There are 4 function keys on the control panel and remote controller.
(arm-away, arm-stay, disarm and panic)
-10-
XX=01~16 (16 wireless zones)
XX=17 (Panic key on remote controller and
keypad.)
-23-