The factory default setting is all wireless zones are type 4(panic zone).
Wired zone 21 is type 1(entry/exit zone), Wired zone 22 is type 2(active zone),
Wired zone 23 is type 3(perimeter zone) Wired zone 24 is type 4(panic zone)
Functions:
Set different zone types .It can not modify the zone types of the
zone 17(panic zone), the zone 18 (duress password zone) and the zone
type of the No.30 (control panel anti-tamper zone)
For example:
Set wired zone 21 as gas zone, wireless zone 3 as fire alarm zone,
Arm-away
Arm-stay
Disarm
Panic
press (PROG
user password
#)
40
21
6
#
40
03
5
#
Note:
When the system is in arm- away status, all zones are valid; when the
system is in arm- stay status, active zone is bypassed but other zones are
still valid ; when the system is in disarm status, fire alarm zone, gas zone,
panic zone, anti-tamper zone and duress zone are still valid.
8.1 Arm-away
Figure 10
9.3.20 Enroll wireless zone detector
Enter: 61 XX
1. When the system is in disarm/arm-stay status, press 'AWAY' key on the
control panel or 'Arm-away' key on the remote controller, armed
Operations: (PROG
user password #) 61
XX
#
indicator on, buzzer beeps 'Di-Di', the system is in exit-de lay and LCD
Parameters setting:
XX=01~16, indicating zone number of wireless detector .
Functions:
Enroll wireless detectors as required.
For example:
Enroll NO.03 wireless zone detector
displays:
Arming...
press: (PROG
user password
#)
61
03
#
The keypad buzzer will stop after exit-delay expired, LCD displays:
Learning code...
60 sec
The code learn operation time is about 60 seconds .During this period,
trigger the zone detector with code learn, buzzer chirps once to indicate
code lean successful, LCD displays:
Input Command
If the system hasn't received the wireless signal at the end of operation time,
it indicate the code learn failure, buzzer chirps 5 times, LCD displays:
Program Fail!
If code learn fail after trying and trigger the detector many times, there will
be two reasons: First, the enrolling code learn has been used by other
detector in the system; Second, the enrolling code learn has been used by
-22-
Arm-away
Year-Month-Day Hour: Minute
2. When the system is in zone alarm status, press 'AWAY' key on the
control panel or 'Arm-away' key on the remote controller, LCD displays:
Can't arm
Please disarm
3. In Arm-away status, the 'AWAY' key on the control panel is invalid.
8.2 Arm-stay
The arming mode can be applied when user is at home. All zones are in
armed status except 'Active Zone'.
1) If the control panel is in disarmed status, press the 'STAY' key on the
control panel or 'Arm-stay' key on the remote controller, armed
indicator flashes, buzzer chirps once and LCD displays:
Arm-stay
Year-Month-Day Hour: Minute
-11-