LONGHORN LHD8001 Скачать руководство пользователя страница 15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

The factory default setting is all wireless zones are type 4(panic zone). 
Wired zone 21 is type 1(entry/exit zone), Wired zone 22 is type 2(active zone), 
Wired zone 23 is type 3(perimeter zone) Wired zone 24 is type 4(panic zone) 

Functions:

 Set different zone types .It can not modify the zone types of the 

zone 17(panic zone), the zone 18 (duress password zone) and the zone 
type of the No.30 (control panel anti-tamper zone) 

For example:

 Set wired zone 21 as gas zone, wireless zone 3 as fire alarm zone, 

Arm-away 

Arm-stay 

Disarm 

Panic 

press (PROG 

user password 

#) 

40 

21 

40 

03 

Note:

 When the system is in arm- away status, all zones are valid; when the 

system is in arm- stay status, active zone is bypassed but other zones are 
still valid ; when the system is in disarm status, fire alarm zone, gas zone, 
panic zone, anti-tamper zone and duress zone are still valid. 

 
 

8.1 Arm-away 

Figure 10 

9.3.20 Enroll wireless zone detector 

Enter: 61 XX 

1. When the system is in disarm/arm-stay status, press 'AWAY' key on the 

control panel or 'Arm-away' key on the remote controller, armed 

Operations: (PROG 

user password #) 61 

XX 

indicator on, buzzer beeps 'Di-Di', the system is in exit-de lay and LCD 

Parameters setting:

 XX=01~16, indicating zone number of wireless detector . 

Functions:

 Enroll wireless detectors as required. 

For example:

 Enroll NO.03 wireless zone detector 

displays: 

 

Arming... 

press: (PROG 

user password 

#) 

61 

03 

The keypad buzzer will stop after exit-delay expired, LCD displays: 

 

Learning code... 

60 sec 

 

The code learn operation time is about 60 seconds .During this period, 
trigger the zone detector with code learn, buzzer chirps once to indicate 
code lean successful, LCD displays: 

 

Input Command 

 

 

 

If the system hasn't received the wireless signal at the end of operation time, 
it indicate the code learn failure, buzzer chirps 5 times, LCD displays: 

 

Program Fail! 

 

 

If code learn fail after trying and trigger the detector many times, there will 
be two reasons: First, the enrolling code learn has been used by other 
detector in the system; Second, the enrolling code learn has been used by 

 

-22- 

Arm-away 

Year-Month-Day Hour: Minute 

 

2. When the system is in zone alarm status, press 'AWAY' key on the 

control panel or 'Arm-away' key on the remote controller, LCD displays: 

 

Can't arm 
Please disarm 

 

3. In Arm-away status, the 'AWAY' key on the control panel is invalid. 

 

8.2 Arm-stay 

The arming mode can be applied when user is at home. All zones are in 

armed status except 'Active Zone'. 
1) If the control panel is in disarmed status, press the 'STAY' key on the 

control panel or 'Arm-stay' key on the remote controller, armed 
indicator flashes, buzzer chirps once and LCD displays: 

Arm-stay 

Year-Month-Day Hour: Minute 

 

-11-

Содержание LHD8001

Страница 1: ...MGE Entreprise Av Kouwait 8050 Hammamet Tunisie Tel 1 00216 72 278 663 Tel 2 00216 22 645 120 Email manager mge security com www mge security com INSTALLATION MANUAL LHD8001 SECURITY SYSTEM...

Страница 2: ...2 Remote Controller 2 3 Wireless Passive Infrared Detector 1 4 Wireless Magnetic Switch 1 5 Power adapter 1 6 Installation manual 1 7 Telephone line 1 8 Accessories bag 1 Zone number Installation pos...

Страница 3: ...assignment 7 1 Zone type 10 10 24 Zone bypass 25 Zone reactivate 26 Voice recording 27 Record playing 28 Viewing event log 65 66 70 71 80 X X 0 X X X 01 16 16 wireless zones X 21 24 4 wired zones No b...

Страница 4: ...All remote controllers canceling 9 3 34 Zone type initialization 9 3 35 System default restoring 10 Remote telephone operation 10 1 Telephone disarm 10 2 Telephone arm away 27 27 27 27 28 28 28 4 Oper...

Страница 5: ...nect to 2 2K resistance 2 Control device Remote controller Keypad Local or remote telephone system 3 Wireless frequency 315MHz 433MHz 868 MHz optional Communication protocol ADEMCO 4 1 and Contact ID...

Страница 6: ...s The station will take corresponding actions after receiving the alarm Entry delay A period for user to enter detection area activate the delay zone and disarm before the system alarms During the per...

Страница 7: ...rm Arm 11 21 15 Remote controller arm disarm Disarm arm operation by using the type and of the detector Confirm the installation position and wiring direction according to the specific condition Make...

Страница 8: ...y is well charged it can supply the system with power more than 14 hours low battery it can supply power more than 1 5 hours Low battery power indi cator f lashe s fast when AC power is low voltage po...

Страница 9: ...telephone if there is no voice Zone N C Detector after receiving the telephone or user unwilling to wait pressing any key key 5 recommended the control panel will play voice information immediately A...

Страница 10: ...rs are canceled Please use standby battery to ensure the control panel can work normally when AC power failure 9 3 33 All remote controllers canceling Enter 940 Fix the control panel to the wall by sc...

Страница 11: ...ftware version of CPU are not identical LCD displays Version vary and buzzer beeps user can cancel the alarm by disarm command In this condition it is better to inform the supplier in time This operat...

Страница 12: ...play Arm away Year Month Day Hour Minute Indicating the system is in arm away status the present time is Year Month Date Hour Minute or the system is in arm stay or disarm status The corresponding dis...

Страница 13: ...is in zone alarm status and the zone be triggered again the Operations PROG user password 66 XX system will prompt zone alarm only but entry delay Parameters definition XX means reactive bypassed zone...

Страница 14: ...avoid influence from wireless clutter wave During the code learn operation only the key is valid press this key to exit the code learn operation status 9 3 21 Wireless zone detector canceling Enter 6...

Страница 15: ...etector Functions Enroll wireless detectors as required For example Enroll NO 03 wireless zone detector displays Arming press PROG user password 61 03 The keypad buzzer will stop after exit delay expi...

Страница 16: ...e If user wants to cancel some set disarming time set YYYY as 8888 For example Set 08 00 and 22 00 as disarm time press PROG user password 36 1 0800 36 2 2200 Program press user password or operation...

Страница 17: ...32 10 alarm indicator on buzzer chirps continually LCD displays 9 3 15 Date setting Enter 33 XXXX ZONE 17 Panic Year Month Day Hour Minute Operations PROG user password 33 XXXX Parameters definition X...

Страница 18: ...no delay XX 01 10 seconds XX 02 20 seconds Following the cursor input the commands If the input digits are incorrectly press key to delete them then press key to confirm If the XX 10 100 seconds inpu...

Страница 19: ...tions The system can be set 6 groups of alarm telephone number NO 9 3 10 Relay output type setting Enter 28 X 1 is for the center stations If alarm happens the system will call center stations and sen...

Страница 20: ...assword user should ensure its safety and reliability Restore password in factory default setting Hardware restores factory 9 3 6 Bell ON OFF setting Enter 24 X default setting There is a jumper CB400...

Отзывы: